CHAPTER 6
29
Cleanness during assembly
When working with hydraulic systems three basic rules must be observed.
•
RULE 1: CLEANNESS when assembling the hydraulic system.
•
RULE 2: CLEANNESS during every-day operation of the hydraulic system.
•
RULE 3: CLEANNESS during control and repair works.
Rule 1:
Cleanness when assembling the hydraulic system.
Hoses, tubes, and screw joints are never clean after adjusting and must therefore always be
cleaned immediately before assembly.
Tubes - also bent tubes – are cleaned using a ball of crepe paper or lint-free cloth which is drenched with
paraffin and put into one end of the tube. Then compressed air is blown through the tube.
Repeat this procedure with several balls until they are clean when they leave the tube.
If the tubes have been bent or welded, they must be cleaned by pickling with hydrochloric acid and
then rinsed with cold and warm water and dried.
If the tubes are not mounted and filled with oil immediately after cleaning, they must be greased with
hydraulic oil and plugged up, otherwise they will get rusty. Furthermore, remove the cover plugs on all
pumps, engines, valves, etc. only immediately before assembly.
Содержание PSM400-16
Страница 10: ...CHAPTER 3 7 CHAPTER 3 Overview of tools In this chapter General 8 Check of threaded fasteners 9...
Страница 15: ...CHAPTER 4 12 CHAPTER 4 Crane handling In this chapter Crane handling 13 Storage 16...
Страница 37: ...CHAPTER 8 34 CHAPTER 8 Power Pack In this chapter Filling the power pack tank 34...
Страница 44: ...CHAPTER 10 41 CHAPTER 10 Post assembly check In this chapter Post assembly check 42...
Страница 47: ...CHAPTER 11 Commissioning In this chapter Commissioning 44 Term Definitions 44...
Страница 49: ...CRANES LIFESAVING EQUIPMENT WINCHES AND HANDLING EQUIPMENT SERVICE 2021 11 15 Revision 3 0 NOV...