background image

 

DICHIARAZIONE DI CONFORMITÀ UE 

EU DECLARATION OF CONFORMITY

 

 

14/14 

 
 

Standards and/or technical specifications applied 

Norme e/o specifiche tecniche applicate 

 

Directive 2014/34/EU 

Direttiva 2014/34/UE 

Standard 

Norma 

Title 

Titolo 

EN 60079-0:2012 
EN60079-0/A11:2013 

Explosive atmospheres - Part 0: Equipment - General requirements 

Atmosfere esplosive - Parte 0: Apparecchiature - Prescrizioni generali 

EN 60079-15:2010 

Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 

Atmosfere Esplosive - Parte 15: Apparecchiature con modo di protezione "n" 

EN 60079-31:2014 

Explosive atmospheres - Part 3

1: Equipment dust ignition protection by enclosure “t” 

Atmosfere Esplosive - 

Parte 31: Apparecchi con modo di protezione “t” destinati ad essere utilizzati in presenza di polveri 

combustibili 

 

Directive 2014/35/EU

 

Direttiva 2014/35/UE 

Standard 

Norma 

Title 

Titolo 

EN 60947-1:2007 
EN 60947-1/A1:2011 
EN 60947-1/A2:2014 

Low-voltage switchgear and controlgear 

– Part 1: General rules 

Apparecchiature a bassa tensione - Parte 1: Regole generali 

EN 60947-3:2009 
EN 60947-3/A1:2012 
EN 60947-3/A2:2015 

Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units 

Apparecchiatura a bassa tensione 
Parte 3:Interruttori di manovra,sezionatori,interruttori di manovra-sezionatori e unità combinate con fusibili 

 

Directive 2011/65/EU 

Direttiva 2011/65/UE 

Standard 

Norma 

Title 

Titolo 

EN 50581:2012 

Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous 
substances 

Documentazione tecnica per la valutazione dei prodotti elettrici ed elettronici in relazione alla restrizione delle sostanze 
pericolose 

 

In addition, the products covered by this declaration are in conformity with the following IEC standards: 

I prodotti oggetto della presente dichiarazione sono in oltre conformi alle seguenti norme IEC: 

 

IEC standard 

Norme IEC 

ed. 

Title 

Titolo

 

IEC 60079-0:2011 
+ISH1: 2013 
+ISH2:2014 
COR:2012 

6.0 

Explosive atmospheres - Part 0: Equipment - General requirements 

Atmosfere esplosive - Parte 0: Apparecchiature - Prescrizioni generali 

IEC 60079-15:2010 

4.0 

Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 

Atmosfere Esplosive - Parte 15: Apparecchiature con modo di protezione "n" 

IEC 60079-31:2013 

2.0 

Explosive atmospheres - Part 31: 

Equipment dust ignition protection by enclosure “t” 

Atmosfere Esplosive - Parte 31: Apparecchi con modo di protezione mediante custodie 

“t” destinati ad essere utilizzati in 

presenza di polveri combustibili 

 
 
 

Содержание CAM-EX Series

Страница 1: ...xed installation CAM EX Series ATEX EXECUTION INTERRUTTORI E COMMUTATORI IN CASSETTA IN LEGA DI ALLUMINIO Per installazione fissa Serie CAM EX ESECUZIONE ATEX Execution Esecuzione Group II Category 3G...

Страница 2: ...l dimensions Dimensioni esterne mm 272146EX 3 16 A Ex nR IIC T5 T6 Gc Ex tb IIIC T85 C Db 125 x 185 272147EX 4 16 A 125 x 185 272246EX 3 25 A 125 x 185 272247EX 4 25 A 125 x 185 272306EX 3 40 A 125 x...

Страница 3: ...in conformity with the operated parameters established by the manufacturer and ensuring a high level of protection D Equipment intended for use in the presence of combustible dust Equipment suitable f...

Страница 4: ...esso un atmosfera esplosiva sotto forma di nube di polvere combustibile nell aria Zone 1 A place in which an explosive atmosphere consisting of a mixture of air and inflammable substances in the form...

Страница 5: ...places with an atmosphere with the presence of combustible dust the ignition temperature of the dust is greater than the temperature indicated in the marking according to hazardous areas installation...

Страница 6: ...Terminals of the switches and commutators 16 A Morsetti degli interruttori e commutatori da 16 A 1 4 Terminals of the switches and commutators 25 A Morsetti degli interruttori e commutatori da 25 A 1...

Страница 7: ...t Cavo uscita mm A mm B mm C mm D mm E mm F mm 272141EX 12 18 137 5 102 92 92 77 77 272142EX 272143EX 272144EX 148 185 125 110 170 272241EX 137 5 102 92 92 77 77 272242EX 272243EX 272244EX 148 185 125...

Страница 8: ...2246EX 272247EX 272306EX 16 25 16 25 148 185 125 110 170 272307EX 168 282406EX 282407EX 190 252 185 235 171 Isolator and selector switches must be installed according to this instruction These switchg...

Страница 9: ...by alternate current in accordance with par 2 The switchgear must never be used with continuous current When the switchgear is used at the rated current the switchgear must be connected with maximum...

Страница 10: ...spettare quanto segue Utilizzare solo cavi con guaina Utilizzare solo cavi secondo quanto previsto dal capitolo 2 del presente documento Rimuovere la guaina del cavo solo per lo stretto necessario a s...

Страница 11: ...N AND DON T MAKE MAINTENANCE WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT ATTENZIONE NON APRIRE L APPARECCHIO E NON ESEGUIRE OPERAZIONI DI MANUTENZIONE QUANDO IN TENSIONE NON APRIRE E NON ESEGUIRE OPER...

Страница 12: ...oblem cannot be solved contact manufacturer In caso di guasto sostituire le guarnizioni e o i pressacavi e ripetere il test In caso di nuovo esito negativo contattare il costruttore 8 3 RESTRICTED BRE...

Страница 13: ...on IP code Grado di protezione codice IP IP66 IP67 solo codice 282407EX IP65 Rated Voltage Tensione nominale 110 230 400 500 Vac Rated Current Corrente nominale 16 25 40 63 A Frequencies Frequenze 50...

Страница 14: ...and fuse combination units Apparecchiatura a bassa tensione Parte 3 Interruttori di manovra sezionatori interruttori di manovra sezionatori e unit combinate con fusibili Directive 2011 65 EU Direttiv...

Отзывы: