74
004778003
-
21/02/2023
distribution outlet
(C)
on the other side, securing it with a hose clamp.
When the stove is used to heat two or more adjacent rooms, it is essential to encourage recirculation of the ambient
air to uniform the temperature in the various rooms.
For air ducting, preferably use smooth, internally insulated pipes.
To connect the stove to the ducted heating system, connect a pipe
(B)
to the rear fan
(A)
on one side and to the air
distribution outlet
(C)
on the other side, securing it with a hose clamp.
When the stove is used to heat two or more adjacent rooms, it is essential to encourage recirculation of the ambient
air to uniform the temperature in the various rooms.
For air ducting, preferably use smooth, internally insulated pipes.
7.5.1 PRO 2
Room thermostat for rear fan control (PRO 2)
It is possible to connect a room thermostat to the terminal board of the stove so that the rear fan can be switched
on and off according to the temperature set on the thermostat.
To use this function, rear fan ventilation must be set to ON.
The thermostat that controls the rear fan must be connected to terminals 5 and 6 of the terminal board in place of
the bridge.
A
B
C
TA
Fig. 37
22.15 20.3 °C
1
2
3
4
5
6
T
1
6
22.15 20.3 °C
Fig. 38