68
004778003
-
21/02/2023
6.6 Roof exhaust with traditional fireplace
The chimney for the evacuation of flue gases must be made by qualified personnel in compliance with standards
UNI 10683- EN 1856-1-2- EN 1857-EN 1443- EN 13384-1-3- EN 12391-1 both in terms of the dimensions and the materi-
als used in its construction.
The flue gases can be evacuated through a traditional chimney (
Fig. 25 - “Fig. 26”
-) provided the good condition
and proper maintenance of the chimney has been verified. In the case of an old chimney, it is advisable to renew it
using ducting.The flue gas exhaust must be on the roof.
UPPER OUTLET
1)
Wind-proof cowl
2)
Seal
3)
Inspect
1)
Non-combustible material
2)
Steel piping
3)
Closing panel
1
3
2
Fig. 25
1
3
2
Fig. 26