Page  12.

 

 

-

 

Check the gas supply and the pressure of the socket 

on the solenoid valve that measures the noodles 

 

The device is not working after repeatedly attempting to 
start the ignition cycle 

 

Possible causes: 

 

-

 

Solenoid valve damaged 

-

 

Electrical connection between ignition and control 

electronics 

 has been  severed

 

-

 

 Inappropriate pressure on the injector  

-

 

 Incorrect troubleshooting options:   

-

 

Replacement of solenoid valve 

-

 

 Check  the  electrical  connection  between    the 

ignition device and the electronics control  
-

 

Check the gas supply and the pressure of the socket 

on the solenoid valve that measures the noodles 

 

The gas burner starts, but after a while  the flames go 

out 

 

Possible causes: 

 

-

 

Confused zero and phase wire  

-

 

 Inappropriate pressure on the injector  

-

 

  Air flow controller  returns to its original position  

 

 Troubleshooting options : 

 

-

 

 Verify that the stage is correct  

-

 

Check the gas supply and the pressure of the socket 

on the solenoid valve that measures the noodles 
-

 

Check the position of the airflow controller - if it is 

 in 

 

its  original  position,  check

  for 

  any  stickyness,  if 

necessary, clean it. 

 

STORE 

 
 

 

Place  the  plastic  gas  connection  caps  removed  when 
unpacking the device. 

       After each disconnect from the gas grid, change the 

gasquet to a flexible gas hose. 
Store  the  device  in  a  covered,  dry  room,  protecting  it 
from mechanical damage. 

SERVICE AND 
PREVENTIVE 
MAINTENANCE 

Preventive maintenance 

 

LH  heat  generators,  in  addition  to  inspection  and 
cleaning,  do  not  require  special  care  (see  preventive 
maintenance performed by the user).  However, in order 
to  ensure  work  safety  and  long  service  life,  it  is 
recommended  to  conduct  an  annual  inspection  by  an 

authorized service specialist. 

 

 User-defined preventive maintenance 

 

(a)  Inspection  and  cleaning  of  appliance  housing.   
Remove the dust from the surface of the casing with 

a brush or air and make sure there are no stains or 
burnt parts. 
b) Visually check through the loophole the state of 
the flame's residual disc.  Color burnout or coloring 

is clearly visible in the visual inspection.  
c) Check the suspensions, make sure that the load 
in the suspension areas is evenly distributed.  This 
can  be  done  by  moving  each  suspension 
separately.  
d)  Clean  and  check  the  fan:  Check  the  fan  pane 
rotation, make sure the fan blades spin freely, if the 
blades are dirty, clean them.  

) Manually control the airflow 

controller , manually transfer the 

 microswitch 

several  times.    Check  the  presence  of  spring.    If 
necessary, air purify the controller. 

 

     If working conditions (environmental contamination, 
e.g.  dust,  fumes)  require  this,  inspection  and  cleaning 
should be carried out more often!  The main reason for 

this  is  that  the  layer  of  dust  deposited  on  the  fan 
exacerbates the efficiency of the device and significantly 

increases  its  weight,  an  important  factor  in  terms  of 
suspension safety. 
The  device  is  suitable  for  heating  greenhouses,  in 
animal milking (poultry houses, pigs). 
Attention: If the device is used in agriculture (e.g. animal 

masculinity) or in such  

             ATTENTION : If you plan not to use the device 

for a long time, be sure to turn off the power and connect 
the throttle .

 

READ  MORE:  Never  perform  possible 

maintenance on a panic or an energy appliance .

 

Содержание LH-30

Страница 1: ...o set back the tone of the methane in this year can lead to a job Unworthy of this accepted cooperative back occurs during work Slime said the claims were not ed Poguy s request stipulates in this art...

Страница 2: ...roviding air supply 5 Device Installation 6 Suspend Device6 Connecting Power 7 Instrument Control 7 Commission 8 Instrument 8 Start Failures RESET 8 Disable device9 Possible defects and methods elimin...

Страница 3: ...r required for combustion and ventilation is indicated in Annex No 1 of this manual Protect the device from the following possible impacts wind strong water rain or drip of water Do not use the device...

Страница 4: ...CTERISTICS OF THE DEVICE The hole blows out the hot air Open it Box Device Remove From Her Parts Part Then Remove Protective Covers from device e g polostirene or etc Remove the protective gas cap imm...

Страница 5: ...imum throttle pressure sensor must be installed Air flow sensor Rice 3 Burner security elements In connection with the continuous work on improving the device increasing its reliability and quality ch...

Страница 6: ...1 207 86 kJ m K T temperature difference in Kelvin 110 100 value returns a 10 premium for rapid warming 103 100 value pays a surcharge of 3 on loss of body heat See the example of the calculation in t...

Страница 7: ...at least 400 mm Fasten it suspension under Roof Or Ceiling On Reference beams or supports between pillars or Against the wall The suspension of the device is performed with the help of the ears Locat...

Страница 8: ...that means the air temperature in the room is higher than the above This is it will continue until the air temperature in the room drops below the temperature set on the thermostat and the thermostat...

Страница 9: ...to constantly monitor the temperature of the casing If the housing temperature reaches 134 the controller immediately sends a signal to control which in turn off the device and the red button light si...

Страница 10: ...eventive maintenance performed by the user However in order to ensure work safety and long service life it is recommended to conduct an annual inspection by an authorized service specialist User defin...

Страница 11: ...mbar Maximum 60 mbar Fan Motor 150W Operational Voltage230V 50Hz 2 1A Electrical Requirements2 1A Weight 23 1 kg Usable power Typ e LH 30 LH 40 LH 50 LH 60 LH 70 LH 80 Usable power 31kW 39 kW 51 kW 5...

Страница 12: ...umption for incoming air H is calculated as follows H A V C v T x 10 3 Where is A number of air exchanges per hour V room volume Cv specific air heat 1 207 kJ m3K T Temperature difference in Calvin 3...

Страница 13: ...Motorcycle fan Heat Regulator Minimum gas controller 4 Ghani thermostat 5 Air flow sensor 6 Squash sensor 7 Ionitaization of flame 8 Candles be Solenoid valve Capacitor...

Страница 14: ...ree for this purpose the defective unit must be sent to the manufacturer by an act drafted by the gas management representative together with the owner of the heater The act indicates a factory number...

Отзывы: