Page 12.
DESIGN AND PRINCIPLE DO
DEVICE
Gas supply system : For the safe operation of the
device, the pressure on the gas on the grid must be at
least 30 mbar, but not over 60 mbar.
After connecting the gas connection kit to the grid
and device, open the gas tap, after which the gas
will begin to be supplied through the gas filter,
solenoid valve, noodles in the combustion chamber.
Air supply system : The engine will turn the fan
blades, which in turn will provide the necessary air
flow within the device. The flow of air created in
this way, dragging with it heat created during the
combustion of the gas-air mixture and combustion
products formed during this process, is fed in the
heated zone.
Ignition system : The control electronics according
to the specified temperature parameters give an
electric signal of high voltage to the candle, which
under this influence begins to spark and thereby
ignites the gas mixture.
Security and control system : For your safety , the
device is equipped with three sensors
-
flame ionization control
-
Air flow sensor
-
overeating sensor
In some countries, such as Ukraine, Russia, etc.,
according to the requirements, a fourth sensor
- a minimum throttle pressure sensor - must be
installed.
Air flow sensor
Rice. 3 security elements.
In connection with the continuous work on
improving the device, increasing its reliability and
quality, changes can be made to the design of the
device that is not reflected in this documentation.
DEVICE INSTALLATION
Gas supply system
Combined Electromagnetic Valve
ionization flame controller
air combustion
, heating of air
Rice. 2 Device in + principle of operation
The gearbox is installed separately in front of each
device or single common gearbox on the central gas
supply pipe. Before each device, a filter must be
installed to prevent a solenoid valve from blocking due
to possible contamination of the pipeline (despite the
fact that the solenoid valve is blocked) to clean them).
Connecting to the main pipeline is being implemented
top or side, since the link at the bottom will be Serve
Collection Pollution What Can Influence On Normal Do
Device.
certification
sensor
certification
sensor
Opposing fuses and flame stitches
RELATED: LH heat generators-...
it can only
work
with
gas
in
The devil's
mind.
When working on natural gas, it's over 90
milligrams.
When working on the body throttle, the overtake of
the gas is 50 mbar.
The gas too heavy is 60 milligrams.
STYLES: If the gas needs to exceed 60 mbar. - During
the
the course of the reduction
Against if it had to
.