Page 12.
Rice. 6 Total Device Dimensions
Power
[kW]
Total Dimensions
(mm
)
D
L
30 kW
435
1130
40 kW
435
1130
50 kW
435
1130
60 kW
435
1130
70 kW
435
1130
80 kW
435
1130
Rice. It's a similar. 7: Distance between hanging
mountains
Distance,
safety
and fire protection requirements: Distance depends on
device strength
Rice. 8 Minimum safety and fire protection distance.
Power
[kW]
Protective distances, mm
And
B
C
D
30 kW
300 1200 500
500
40 kW
300 1350 500
500
50 kW
450 1500 500
500
60 kW
450 1650 500
500
70 kW
450 1800 500
500
DEVICE PENDANT
For Warning Deformation as a consequence of Heat
Extensions Length Suspension (e.g. chain) must be at
least 400 mm. Fasten it suspension under Roof Or
Ceiling On Reference beams or supports, between
pillars or Against the wall. The suspension of the device
is performed with the help of the ears, Located On His
Housing.
Rice. 8 Suspend device
When suspended, the device is installed horizontally,
the maximum
allowed
deviation is +5 / -5 º.
POWER CONNECTION
- the device is connected to the main secure jack in the
control unit (box).
-
How to connect to a network:
Using a grounded plug or fixed connection taking into
account the correct stage,
-
max. electrical consumption of device 1.5 A
-
Mains power cord: 3x0.75 MT cable
-
The device is
sensitive
to stage, so the connection
must be made as indicated in the picture.
L – Phase
N – Zero
Country
An electric power diagram with Brahma automation is
provided in Annex No. 2.
80 Kw
450 1950 500
500
590
+5
-5