Section 150-441-124
June 12, 1997
Revision 01
Page 26
PairGain Engineering - Plant Series
HiGain HLU-D41
17. Set Clock
17.1
Press <B> from the Maintenance Terminal Main menu to open the Set Clock screen.
The following screen displays:
17.2
Set Time.
The cursor defaults to the "New Time" field. To set the system time, type the hour and
minute in the 24-hour format of hh:m:ss (setting the seconds is optional), then press <Enter>.
The "New Date" field displays.
If you input an invalid entry, the following messages appears followed by the name
of field where the invalid entry occurred:
> error
17.3
Set Date.
To set the system date, type the month, day and year in a mm/dd/yy format, then press
<Enter>.
The "Update Remote" field displays.
17.4
Update Remote.
The remote unit date and time is set using this option. List 1 HRU-512 units
having software versions 6.4 and above, and all List 6, and List 7 HRU-512 units can be set to the
same time and date as the HLU-D41. To update the remote, do one of the following:
Press <U> and the remote unit is updated to the same date and time set for the HLU-D41. All
time information is lost when power is removed. The last date, however, is retained in NVRAM
and reappears when power is restored.
Press <Enter> and the remote unit is not updated.