8.3: Preheating and Starting the Cleaning Cycle 

 

Recommended Temperature Settings for Dissolving 

Soluble Support from 3D Printed Parts 

Build 

Material 

Temperature Setting 

WaterWorks  EcoWorks 

ABS 

70°C 

Yes 

Yes 

PC 

85°C 

Yes 

No 

Nylon 

50, 60 or 70°C** 

Yes 

Yes 

**depending on part wall thickness and desired dimensional accuracy. 

For Polyjet parts select the ‘HEAT OFF’ option. 

 

Connect the power cord to the side of the unit then to a suitable grounded wall socket. 

The unit is compatible with both  North America  110V~50/60Hz  and International 
220V~50/60HZ power.  The unit ships with both  power  cords.  Only use a  power  cord 
provided by the manufacturer. 

It is strongly recommended that the unit be placed on a circuit with its own breaker with a 
GFCI. The power circuit must be grounded. 

Press the ON/OFF rocker switch. The display control panel should be on. 

Press one of the four temperature preset buttons or the Heat Off button to select the cleaning 
temperature. The temperature can be changed at any time during the cycle by selecting a 
different temperature button. If heating the water from room temperature to 70°C, it takes 
about 2 hours to reach temperature. 

Press the SET button and then press the up and down arrows to set the minutes. Press the 
SET button again and use the up and down arrows to set the hours. Press the SET button 
again to accept the time. Press the 

 button to start the heater and pump. 

8.4: Loading Parts and Testing Level Sensors 

Wait until the SCA has reached the desired temperature before loading parts into the tank. 
This minimizes the time the parts are immersed in the cleaning solution. 

Open the lid on the large parts basket and place the parts inside. 

For smaller parts, open the spring-latched door of the smaller, square basket, place the 
part(s) inside and place small basket inside larger basket. 

Before placing the basket into the cleaning solution, press the 

 button to pause the 

heater and pump. With the basket cutout facing the nozzle, slowly lower the large parts 
basket into the solution-filled tank. The spray nozzle should be centered on the basket 
cutout. 

If the high level alert lights and the alarm sounds, press the 

 button to silence the 

alarm, and remove liquid by draining or scooping liquid from the tank until the alert 
indicator is no longer lit. 

Note: It is recommended that the level sensors be tested periodically. Adding water to 
just above the MAX fill line should cause the high level alert to illuminate and the buzzer 
to sound. Draining water until the liquid level is below the MIN fill line should cause the 

Содержание SCA 1200 HT

Страница 1: ...SCAHTUM 03 1 SCA 1200HT User Manual User Manual August 1 2016 Phoenix Analysis Design Technologies Inc PADT Inc TEL 1 800 293 PADT FAX 480 813 4807 sca padtinc com www SupportRemoval com...

Страница 2: ...SCAHTUM 03 2 SCA 1200HT User Manual This page left intentionally blank...

Страница 3: ...4 INSTALLATION 16 8 OPERATING YOUR SCA 17 8 1 FILL THE UNIT WITH WATER 17 8 2 ADD CLEANING CONCENTRATE TO THE TANK 17 8 3 PREHEATING AND STARTING THE CLEANING CYCLE 18 8 4 LOADING PARTS AND TESTING LE...

Страница 4: ...hould be easily accessible at all times Position the unit so that it can be easily reached It is strongly recommended that the unit be placed on a circuit with its own breaker with a GFCI Place the un...

Страница 5: ...warranty The WaterWorks solution that may be added to the unit to aid in support removal contains Sodium Hydroxide Please read and remember the following safety information about this material DANGER...

Страница 6: ...ank before adding large parts to avoid overflow Always operate the unit in a well ventilated location Always operate within environmental temperature range of 10 to 30 degree C Do not use the SCA for...

Страница 7: ...se neglect accident improper installation improper maintenance or improper operation or application or if the machine was improperly repaired or serviced by the customer This warranty is void if the s...

Страница 8: ...ctromagnetic Compatibility EMC Waste Electrical and Electronic Equipment WEEE Restriction of Hazardous Substances RoHS 2004 108 EC 2012 19 EU 2011 65 EU Common Technical Specifications Used for Demons...

Страница 9: ...SCAHTUM 03 9 SCA 1200HT User Manual...

Страница 10: ...fic amount of cleaning solution added see operating instructions The SCA heats the water and circulates the heated water around the parts in the tank The hot solution dissolves the support material wi...

Страница 11: ...t timer 3 Start Pause 4 No heat selection 5 Temperature selection 6 Silence alarm 7 Alert indicator 8 Low water indicator 9 High water indicator 10 Temperature LED display 11 Pump operating LEDs 12 Pr...

Страница 12: ...rinsed after emptying the tank before refilling with fresh liquid The Heater is located behind the perforated Heater Shield It heats the water in the tank The Spray Nozzle directs the flow of liquid i...

Страница 13: ...ceptacle is where the power cord is connected to the unit The plug is a disconnecting device and should be easily accessible at all times 6 2 4 Front Area The Drain Tube and Drain Valve are on the fro...

Страница 14: ...1 Product Identification Tag The Product Identification tag is located on the back of the unit It contains key support information for the SCA including Model Number Part Number Serial Number and cont...

Страница 15: ...ponents in the system Please consult this information when calling for support or ordering replacement parts Figure 7 SCA Assembly Table 1 List of Replaceable Components Large basket Small parts baske...

Страница 16: ...before lifting the SCA from the shipping container Unit weight is approximately 64 lb 29 kg Two or more people should lift the unit out of the packaging and place it on a table or cart 7 3 Inspecting...

Страница 17: ...Refer to section on Maintaining your SCA for disposal instructions The Ecoworks cleaning agent is both user and eco friendly The WaterWorks concentrate will generally remove support material in less t...

Страница 18: ...the SET button and then press the up and down arrows to set the minutes Press the SET button again and use the up and down arrows to set the hours Press the SET button again to accept the time Press t...

Страница 19: ...rts can be checked at any time during a cleaning cycle by opening the lid carefully lifting the Large Parts Basket from the tank turning the basket 90 and resting it on the rear support bracket and fr...

Страница 20: ...cycle is completed and the parts have been removed the system should be turned off by pressing the ON OFF rocker switch Alternatively if the SCA will be used periodically use the 50 C temperature pres...

Страница 21: ...rotective gloves and eyewear when draining the tank You should drain the liquid from the tank if the unit will not be used in the near future or if the liquid needs to be changed out because the clean...

Страница 22: ...used solution is sufficient for most applications More dilution may be required please check your local regulations If you are ever unsure as to which solution was used in your SCA assume that the Wa...

Страница 23: ...cloth Never immerse the system or use a spray nozzle or hose to clean it Any liquid in the electronics area of the system may damage the system and void the warranty Before using any cleaning or deco...

Страница 24: ...the unit is plugged into for a tripped circuit breaker or blown fuse Reset or replace the breaker or fuse as required Power indicator has failed If the time and temperature displays are lit and the r...

Страница 25: ...s going off Silence the buzzer by pressing the button Liquid level is too high or too low Check the indicator lights on the right side of the control panel If either level indicator is on add or remov...

Страница 26: ...ke screen is clogged Drain the tank as instructed in the section Maintaining your SCA Clean the intake screen with a toothbrush until debris is removed from the holes ALWAYS WEAR PROTECTIVE GLOVES AND...

Страница 27: ...aterWorks is a more efficient cleaning concentrate Liquid Level indicators did not turn off when liquid was added removed from the tank Sensors or Indicators have failed Contact technical support Syst...

Страница 28: ...C 85 C Operating Environment Ranges Temperature 5 C 40 C Humidity 0 80 RH Altitude 0 M 2000 M Temperature Control Accuracy 2 C Pump Max Flow Rate 10 GPM 38 LPM Temperature Display Digital LED Readout...

Страница 29: ...der warranty or covered by a maintenance contract contact the Authorized Reseller from whom the unit was purchased Otherwise to receive technical support visit www SupportRemoval com Resources and pro...