PADT SCA 1200 HT Скачать руководство пользователя страница 24

SCAHTUM-03

 

24 

SCA 1200HT User Manual 

10: Troubleshooting 

The SCA has been designed to allow the end user to resolve most operating problems. 
When a problem is encountered, please read through this troubleshooting section.  If a 
resolution is not found, please contact technical support. 

 

High Risk of Electrical Shock 

Always disconnect the unit from power  

before removing the back panel! 

 

 

Problem 

Probable 

Causes 

What to Do 

Power Indicator  

is not Lit after 

pressing the 
button 

Power switch is not 
“On” 

Press rocker switch on the right-hand side of the 
unit to the “On” position. 

Power cord is not 
connected to unit or 
wall 

Check the power cord and make sure it is pushed 
all the way in to the receptacle on the system and 
is securely connected to a grounded wall socket. 

Fuse is blown 

Contact technical support. 

Power circuit has 
tripped 

Check your building circuit breakers, and any 
power strips that the unit is plugged into for a 
tripped circuit breaker or blown fuse. Reset or 
replace the breaker or fuse as required.   

Power indicator has 
failed 

If the time and temperature displays are lit, and the 
rocker switch on the side of the unit is ON, the 
power indicator has probably failed.  Contact 
technical support. 

Pump and 
heater will not 
start 

Power is not on 

Check the power indicator 

 on the front control 

panel.  If it is off press the

 button. If still unlit, 

then proceed to the “Power Indicator is not Lit” 
Problem. 

Timer has not been 
set and started 

The system will only run when the timer is counting 
down. Check the timer display on the control panel.  

  If it is not counting down, press the 

 

button. 

  If the time being displayed is 00:00, then 

add time and start the system. 

Liquid level is too 
high or too low 

Check the indicator lights on the right side of the 
display control panel.  If either level indicator is on, 
add or remove water from the tank until the 

indicator turns off. Press the 

 button to restart. 

ALWAYS WEAR PROTECTIVE GLOVES AND 
EYEWEAR WHEN ADDING OR REMOVING 
LIQUID FROM THE TANK. 

Содержание SCA 1200 HT

Страница 1: ...SCAHTUM 03 1 SCA 1200HT User Manual User Manual August 1 2016 Phoenix Analysis Design Technologies Inc PADT Inc TEL 1 800 293 PADT FAX 480 813 4807 sca padtinc com www SupportRemoval com...

Страница 2: ...SCAHTUM 03 2 SCA 1200HT User Manual This page left intentionally blank...

Страница 3: ...4 INSTALLATION 16 8 OPERATING YOUR SCA 17 8 1 FILL THE UNIT WITH WATER 17 8 2 ADD CLEANING CONCENTRATE TO THE TANK 17 8 3 PREHEATING AND STARTING THE CLEANING CYCLE 18 8 4 LOADING PARTS AND TESTING LE...

Страница 4: ...hould be easily accessible at all times Position the unit so that it can be easily reached It is strongly recommended that the unit be placed on a circuit with its own breaker with a GFCI Place the un...

Страница 5: ...warranty The WaterWorks solution that may be added to the unit to aid in support removal contains Sodium Hydroxide Please read and remember the following safety information about this material DANGER...

Страница 6: ...ank before adding large parts to avoid overflow Always operate the unit in a well ventilated location Always operate within environmental temperature range of 10 to 30 degree C Do not use the SCA for...

Страница 7: ...se neglect accident improper installation improper maintenance or improper operation or application or if the machine was improperly repaired or serviced by the customer This warranty is void if the s...

Страница 8: ...ctromagnetic Compatibility EMC Waste Electrical and Electronic Equipment WEEE Restriction of Hazardous Substances RoHS 2004 108 EC 2012 19 EU 2011 65 EU Common Technical Specifications Used for Demons...

Страница 9: ...SCAHTUM 03 9 SCA 1200HT User Manual...

Страница 10: ...fic amount of cleaning solution added see operating instructions The SCA heats the water and circulates the heated water around the parts in the tank The hot solution dissolves the support material wi...

Страница 11: ...t timer 3 Start Pause 4 No heat selection 5 Temperature selection 6 Silence alarm 7 Alert indicator 8 Low water indicator 9 High water indicator 10 Temperature LED display 11 Pump operating LEDs 12 Pr...

Страница 12: ...rinsed after emptying the tank before refilling with fresh liquid The Heater is located behind the perforated Heater Shield It heats the water in the tank The Spray Nozzle directs the flow of liquid i...

Страница 13: ...ceptacle is where the power cord is connected to the unit The plug is a disconnecting device and should be easily accessible at all times 6 2 4 Front Area The Drain Tube and Drain Valve are on the fro...

Страница 14: ...1 Product Identification Tag The Product Identification tag is located on the back of the unit It contains key support information for the SCA including Model Number Part Number Serial Number and cont...

Страница 15: ...ponents in the system Please consult this information when calling for support or ordering replacement parts Figure 7 SCA Assembly Table 1 List of Replaceable Components Large basket Small parts baske...

Страница 16: ...before lifting the SCA from the shipping container Unit weight is approximately 64 lb 29 kg Two or more people should lift the unit out of the packaging and place it on a table or cart 7 3 Inspecting...

Страница 17: ...Refer to section on Maintaining your SCA for disposal instructions The Ecoworks cleaning agent is both user and eco friendly The WaterWorks concentrate will generally remove support material in less t...

Страница 18: ...the SET button and then press the up and down arrows to set the minutes Press the SET button again and use the up and down arrows to set the hours Press the SET button again to accept the time Press t...

Страница 19: ...rts can be checked at any time during a cleaning cycle by opening the lid carefully lifting the Large Parts Basket from the tank turning the basket 90 and resting it on the rear support bracket and fr...

Страница 20: ...cycle is completed and the parts have been removed the system should be turned off by pressing the ON OFF rocker switch Alternatively if the SCA will be used periodically use the 50 C temperature pres...

Страница 21: ...rotective gloves and eyewear when draining the tank You should drain the liquid from the tank if the unit will not be used in the near future or if the liquid needs to be changed out because the clean...

Страница 22: ...used solution is sufficient for most applications More dilution may be required please check your local regulations If you are ever unsure as to which solution was used in your SCA assume that the Wa...

Страница 23: ...cloth Never immerse the system or use a spray nozzle or hose to clean it Any liquid in the electronics area of the system may damage the system and void the warranty Before using any cleaning or deco...

Страница 24: ...the unit is plugged into for a tripped circuit breaker or blown fuse Reset or replace the breaker or fuse as required Power indicator has failed If the time and temperature displays are lit and the r...

Страница 25: ...s going off Silence the buzzer by pressing the button Liquid level is too high or too low Check the indicator lights on the right side of the control panel If either level indicator is on add or remov...

Страница 26: ...ke screen is clogged Drain the tank as instructed in the section Maintaining your SCA Clean the intake screen with a toothbrush until debris is removed from the holes ALWAYS WEAR PROTECTIVE GLOVES AND...

Страница 27: ...aterWorks is a more efficient cleaning concentrate Liquid Level indicators did not turn off when liquid was added removed from the tank Sensors or Indicators have failed Contact technical support Syst...

Страница 28: ...C 85 C Operating Environment Ranges Temperature 5 C 40 C Humidity 0 80 RH Altitude 0 M 2000 M Temperature Control Accuracy 2 C Pump Max Flow Rate 10 GPM 38 LPM Temperature Display Digital LED Readout...

Страница 29: ...der warranty or covered by a maintenance contract contact the Authorized Reseller from whom the unit was purchased Otherwise to receive technical support visit www SupportRemoval com Resources and pro...

Отзывы: