MS connectors
connection
The figure below shows the connections required between the
6430 J3 connector and Pacific Scientific stepper motors having
MS connectors. Connections are shown for 4 lead motors, 8
lead motors with paralleled windings, and 8 lead motors with
series windings.
2 - 14
6430 Installation and Hardware Reference Manual - Rev 1
MS CONNECTOR
MS CONNECTOR
MS CONNECTOR
CASE
CASE
CASE
DRIVE/EARTH
GROUND
DRIVE/EARTH
GROUND
DRIVE/EARTH
GROUND
FOUR LEAD MOTOR
EIGHT LEAD MOTOR CONNECTED IN PARALLEL
EIGHT LEAD MOTOR CONNECTED IN SERIES
A
A
A
A
A
A
B
B
B
B
B
B
A
B
C
D
E
TO J3-1
TO J3-1
TO J3-1
TO J3-2
TO J3-2
TO J3-2
TO J3-4
TO J3-4
TO J3-4
TO J3-5
TO J3-5
TO J3-5
TO J3-3
TO J3-3
TO J3-3
A
E
F
B
C
G
H
D
M
A
E
F
B
C
G
H
D
M