SECTION 5
REMOTE OPERATION
85
5.4.1 OUTPUT PARAMETERS (cont)
:[SOURce:]RANGe <n>
sets Output Range Control (for power sources with Range Control).
n
= <0> to <4>. 0 sets the mode to AUTO. See 4.6.3.5
:[SOURce:]IMPEDance:STATE <b>
Enables or disable
optional Programmable Output Impedance function.
b
= <OFF>, <0> or <ON>, <1>
:[SOURce:]IMPEDance <z>
sets the value of the optional Programmable Output Impedance.
z
= varies based on the present configuration and operational mode of
the power source.
Use :SOUR:IMPED:LIM:MIN? and :SOUR:IMPED:LIM:MAX? to
determine the available range.
:[SOURce:]IMPEDance:LIMit:MINimum? <min z>
Query: returns the minimum allowable impedance
:[SOURce:]IMPEDance:LIMit:MAXimum? <max z>
Query: returns the maximum allowable impedance
:[SOURce:]IMPEDance:CAL <z1,z2,z3, x1,z4, x2,z5, x3,z6>
Calibrates the optional Programmable Output Impedance function with
values for:
Description
x values z values
Direct Coupled 1
Φ
z1
Ω
Direct Coupled 2
Φ
z2
Ω
Direct Coupled 3
Φ
z3
Ω
XFMR Coupled - Ratio X
x1
:1
z4
Ω
XFMR Coupled - Ratio Y
x2
:1
z5
Ω
XFMR Coupled - Ratio Z
x3
:1
z6
Ω
x values are transformer ratios. Relation to unity (1) is assumed. For
a 2.5:1 step-up transformer, the x value is 2.5. For a 0.1:1 step-down
transformer, the x value is .1.
z values are the calibrated impedance value, expressed in ohms.
See para. 4.6.3.1.1 for details on this function.
:[SOURce:]IMPEDance:RESet
Resets Programmable Output Impedance calibration values to the
system defaults.
:[SOURce:]TRANSient:AUTO
<b> Sets Transient WFs auto RMS mode.
b
= <OFF>, <0> or <ON>, <1>
See para. 4.6.3.8 for a detailed description.
Содержание UPC-1
Страница 1: ...UPC 3 UPC 1 PROGRAMMABLE CONTROLLERS FIRMWARE V4 25 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE δ ...
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Страница 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 134: ...NOTES 122 NOTES ...
Страница 135: ...MODIFCATIONS 123 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...