SECTION 4
OPERATION
38
4.3.2 VOLTAGE ENTRY
To achieve MANUAL MODE and change voltage, from any meter display light the Va, Vb, Vc LEDs by
pressing those keys.
Pressing an ARROW key (
︿
or
﹀
) causes selected voltages to slew up or down. Entering a number
then pressing
EXECUTE
causes selected voltages to change to the new value. The upper right corner
of the display shows the most recently entered voltage.
For example: To change to 125 volts, light Va, Vb and Vc LEDs as desired by pressing their keys. Type
125
and press
EXECUTE
. The Power Source should now be generating 125 volts.
V/I METER: ENTRY: 125.0
FREQ=60.00 Va=125.0 Vb=125.0 Vc=125.0
SENSE=INT Vab=216.5 Vbc=216.5 Vca=216.5
MANUAL MODE Ia=00.0 Ib=00.0 Ic=00.0
4.3.3 FREQUENCY CONTROL
To achieve MANUAL MODE and change frequency, from any meter display light the F LED by pressing
that key.
Pressing an ARROW key (
︿
or
﹀
) causes the frequency to slew up or down. Entering a number then
pressing
EXECUTE
causes the frequency to change to the new value. The upper right corner of the
display shows the most recently entered frequency.
For example to change to 60.50 Hz. light the F LED: enter
60.50
and press
EXECUTE
. The Power
Source should now be generating 60.50 Hz.
V/I METER: ENTRY: 60.50
FREQ=60.50 Va=120.0 Vb=120.0 Vc=120.0
SENSE=INT Vab=208.0 Vbc=208.0 Vca=208.0
MANUAL MODE Ia=00.0 Ib=00.0 Ic=00.0
4.4
PROGRAM OPERATE MODE
This section describes Program Operate Mode. Program Operate Mode allows pre-stored program
execution including transients.
Not all of the Program Operate features are available with the UPC-3M and UPC-1M manual versions of
the controller. Manual controllers allow editing of VOLTAGE, FREQUENCY, FORM and COUPLING
only.
When the V/I METER display is active, the lower left corner of the display will indicate the PROGRAM #
currently being executed.
Содержание UPC-1
Страница 1: ...UPC 3 UPC 1 PROGRAMMABLE CONTROLLERS FIRMWARE V4 25 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE δ ...
Страница 2: ......
Страница 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Страница 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Страница 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Страница 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Страница 134: ...NOTES 122 NOTES ...
Страница 135: ...MODIFCATIONS 123 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made ...