48 1/8”min
1.22m
GRAVITY VENT AIR INLET
12” min
305mm
FROM OUTER EDGE
OF GRILL TO ANY
CEILING OR WALL.
36”(914mm)min. FROM
THE FLOOR.
Remote Heat Duct Installation
NOTE: ThE ChASE ENCLOSURE MUST hAvE A 30in²
(194 cm²) AIR INLET FOR EvERy REMOTE hEAT kIT
INSTALLED WITh ThE UNIT. NO ChASE AIR INLET IS
REqUIRED IF NOT INSTALLING A REMOTE hEAT kIT.
CONTENTS:
1- OUTLET ADAPTER
1- HEAT DUCT ADAPTER
1- 14"(356mm) X 10"(254mm) OUTLET GRILL
1- 8"(203mm) X 8"(203mm) INLET GRILL
1 - 6"(150mm) ROUND TO 6"(150mm) SQUARE INLET BOOT
1 - INSTRUCTIONS PACK WITH SCREWS
If passing through a wall to an another room or space you
will need a firestop (not included with the WODC.RHKA).
Part #5095.75
TYPE B vent pipe is not included with this kit. A Flex Vent kit
consisting of six 5' lengths is available. Order part #FP30.
FLEXVENT.
INSTALLATION:
1. Using a pair of tin snips, cut away the square section
blocking the heat duct openings and cut out and remove
insulation(Fig.#22).
2. Insert a remote heat flap box in the opening/s that you
are attaching a kit to. Attach the heat duct adapter/s with
the screws provided in the WODC.RHKA (Fig. #22).
heat Duct
openings
heat Duct
Adapters
Fig. #21
Fig. #22
21
5055.7618_210916-32
FP25.BODYA