Fireplace Installation
6. Reverse all previous steps to reinstall the new blower.
Crate Removal
1) Carefully remove wood top and supports.
2) Remove the screws securing the fireplace to the pallet(4).
3) Remove from pallet bottom.
Warning:
Under no circumstances is this heater to be installed
in a makeshift or "temporary" manner. It may be fired only
after the following conditions have been met.
-
DO NOT CONNECT ThIS UNIT TO A ChIMNEy FLUE
SERvING ANOThER APPLIANCE.
-
WARNING:DO NOT INSTALL IN A SLEEPING ROOM.
(MANUFACTURED OR MOBILE hOME ONLy)
- The services of a competent or certified installer, (certified
by the Wood Energy Technical Training program (WETT)
- in Canada, Hearth Education Foundation (HEARTH) - in
U.S.A.,) are strongly recommended.
Locating The FP25 Fireplace
The best location to install your fireplace is determined by
considering the location of windows, doors, and the traffic
flow in the room where the FP25 Fireplace is located,
allowing space in front of the unit for the hearth extension
and the mantel, and taking into consideration the location
of the chimney. Ideally, you should choose a location
where the chimney will pass through the house without
cutting floor or roof joists.
Check the adequacy of the floor by first estimating the
weight of the fireplace system(approx. 500lbs(227Kg)).
Next measure the area the fireplace will occupy. Note the
floor construction and consult your local building code to
determine if any additional support is needed. In most
cases, no additional floor support is needed for the FP25
fireplace.
The FP25 fireplace may be installed directly on a
combustible floor or on a raised base. A minimum of
84"(2.13m) measured from the base of the appliance or
38 3/4"(984mm) from the top of the unit to the ceiling is
required.
The FP25 fireplace may not be installed in a factory built
fireplace unless tested with the fireplace.
Wind direction and magnitude can play a factor in the
chimney performance. Therefore the chimney outlet
position is important when locating the fireplace
We recommend, whenever possible, that the chimney
should:
• Penetrate the highest part of the roof.
• Be installed as far as possible from roof offsets,
trees or any other obstructions that may cause wind
turbulence or back drafts in the chimney.
• Contain the fewest number of offsets (elbows)
possible.
Clearances
Clearances to combustible surfaces and materials are shown
on pages 11 & 16.
Clearances may be reduced with various heat insulating
materials. Consult local, National fire codes and authorities
for approval.
Procedure:
Note: See "Combustion Air" section on page 17.
MAINTAIN CLEARANCES TO COMBUSTIBLES AS
SPECIFIED IN ThE INSTALLATION INSTRUCTIONS
CAUTION: ThE STRUCTURAL INTEGRITy OF ThE
FLOOR, WALL AND CEILING/ROOF MUST BE
MAINTAINED.
ThE SPACE hEATER MUST BE CONNECTED TO A
FACTORy-BUILT ChIMNEy CONFORMING TO CAN/
ULC-S629 OR UL 103hT STANDARDS FOR 650C
FACTORy-BUILT ChIMNEyS.
1. Position fireplace and floor protection in accordance
with the clearances as stated on the label and in these
installation instructions.
2. Mark the position for the hole for the chimney in the
ceiling and roof by using a string and plumb-bob.
3. Check that the intended location will not interfere with
floor joists, ceiling joists or rafters before proceeding
further.
10