FOR USE WITH/

NATURAL GAS/

LP GAS/

EN CASE D’EMPLOI AVEC:

DU GAZ NATUREL DU GAZ LP

Minimum supply pressure / Pression minimum d’alimentation:

5.0 in/wc / 5.0 po/c.e.

11.0 in/wc / 11.0 po/c.e.

(For the purpose of input adjustment / dans le but de régler l’alimenation)

Manifold pressure / Pression de la tuyauterie:

3.8 in/wc / 3.8 po/c.e.

10.0 in/wc / 10.0 po/c.e.

Orifice Size / Diametre de l’injectuer:

# 41

# 53

Input BTU/hr / Entree BTU/h:

Max.:   25,000

Max.:   25,000

Min.:    12,500

Min.:    17,000

Output / Sortie

- Fan On / Ventilateur Allumé

BTU/hr: 18,600

BTU/hr: 18,925

- Fan Off / Ventilateur Position Éteinte

BTU/hr: 17,600

BTU/hr: 17,925

GRAVITY DIRECT VENT WALL FURNACE / RADIATEUR MURAL A ÉVACUATION DIRECTE PAR GRAVITE
VENTED CIRCULATOR OPTIONAL FAN / CIRCULATEUR VENTILE VENTILATEUR OPTIONNELLES

ANS Z21.44a-1992 Direct Vent Wall Furn., CAN1-2.19-M81 Direct Vent Wall Furnace., UL 307B-95
CAN/CGA 2.17-M91 Gas-Fired Appliance For Use At High Altitudes., ANSI Z21.50-1996 / CGA-2.22-M96

This appliance may be converted to a Vented Room Heater with optional "B-Vent Adapter" / Cet appareil pout être
converti à un Radiateur Ventile avec facultatif "B-Vent Adapter"

VENTED ROOM HEATER / RADIATEUR VENTILE - Report No. 476-1070.   

ANS Z21.11.1-1991 Vented Heaters,

CAN1-2.1-M86 Gas-Fired Vented Room Heaters., CAN/CGA 2.17-M91 Gas-Fired Appliance For Use At High Altitudes

Output / Sortie

- Fan On / Ventilateur Allumé

BTU/hr: 18,875

BTU/hr: 19,375

- Fan Off / Ventilateur Position Éteinte

BTU/hr: 17,750

BTU/hr: 18,375

Blower electrical rating:  115v, 60hz, 0.5A / Normes electriques du ventilateur:  115v, 60hz, 0.5 A.
Optional components: B-Vent Adapter / Éléments facultatifs:  B-Vent Adapter.
This appliance equipped for altitudes 0 - 4500 ft. (0 - 1372 m) / Cet unite est concu pour des altitudes variant entre 0 - 4500
pieds (0 - 1372 m). Also certified for installation in a bedroom or a bedsitting room / Aussi certifié pour installation dans une
chambre à coucher ou une salle de séjour.  This appliance must be installed in accordance with local codes, if any; if not,
follow the current CAN/CGA-B149 (Canada), or ANSI Z223.1 (USA).  Cet appareil diot être installé conformemént aux
exigences des codes locaux.  S’il n’existe aucun code local, se conformer à la norme CAN/CGA-B149 en vigueur.

MANUFACTURED (MOBILE) HOME / FABRIQUEZ (MOBILE) MAISON:  May be installed in Manufactured Homes after the "first
sale" - See Instructions.  Pouvez être installés dans a Fabriqué des Maisons après le "première vente"- Voit des Directives.
Install in accordance with the current Standard Mobile Homes, CAN/CSA Z240 MH (in CANADA), and the Manufacturer's
Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for
Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, (in the U.S.A.).  Cet appareil diot être installé
conformemént aux exigences de la norme CAN/CSA Z240 MH en vigueur de l'ACNOR, Installations de gaz dans les
Constructions Mobiles.

Only for direct discharge without duct connection. Pour sortie d'échappement directe sans gaine de distribution seulement.

MINIMUM CLEARANCES TO COMBUSTIBLES / DEGAGEMENT DES MATIERES INFLAMMABLES
Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se determinent
en se mettant devant l’appareil et en lui faisant face.
Recommended service clearance from Right Sidewall to Appliance of 12 in. (305 mm) / II est recommander de laissier
un minimum de 12 po. (305 mm) entre le mur de côté et l'appareil afin de permettre acces de service.

Clearances to Combustibles

Regular Installation

Alcove Installation

Sidewall to Appliance/Du mur lateral a l’appareil

3 in./ 3 po.

(76 mm)

4 3/4 in./4 3/4 po.

(120.6 mm)

Backwall to Appliance/Du mur arriere a l’appareil

1 in./ 1 po.

(25 mm)

1 in./1 po.

(25 mm)

Corner to Appliance/D’un coin a l’appareil

1 in./ 1 po.

(25 mm)

N/A

(N/A)

Alcove Size /

48 in.   Wide Min.

48 po.     Large Min.

Grandeur de l'alcôve

24 in.   Deep Max.

24 po.     Profond Max.

60 in.   High Min.

60 po.     Haut Min.

WARNING:  Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with this appliance.   For assistance or additional information, consult a
qualified installer, service agency or the gas supplier.

Pacific Energy Fireplace Products Ltd.
Duncan, British Columbia, Canada

WH-

REPORT NO. 6563

(JUNE 93)

WH-

MODEL/

SERIES/

MODELE:

  MIRAGE DV

SERIE:

  B

Made in Canada / Fabrique au Canada

Certified for Canada and U.S.A. /
Certifié pour Canada et U.S.A.

040698

5050.7

1-DVB-1

Содержание B Series

Страница 1: ...try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions...

Страница 2: ...ALLATION PRECAUTIONS 7 MANUFACTURED MOBILE HOME 7 STRAIGHT THROUGH WALL 8 CORNER INSTALLATION 9 BASEMENT INSTALLATION 11 FLOOR PROTECTION 11 VENT TERMINAL INSTALLATION 12 LOG SET 13 LIGHTING INSTRUCTI...

Страница 3: ...requent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compart ments burners and circulating air passageways of the appliance be kept...

Страница 4: ...x 3 Fasten in place with the 8 x 1 2 sheet metal screws provided Two screws at the top and three at the bottom of the valve assembly Fig 2 Caution Before making wiring connections ensure all power is...

Страница 5: ...5 Connect Here Fig 4 Fig 3 Optional Wall Switch or Wall thermostat Optional Blower Wiring...

Страница 6: ...Z 80 watts Fig 5 For your protection against shock hazard use only a properly grounded outlet that will accept a three pronged plug Do not cut or remove the grounding prong Consult local codes or in t...

Страница 7: ...er lag screws Consult local codes for approval INSTALLATION PRECAUTIONS The Mirage Gas Appliance installation and venting must con form to the current CAN CGA B149 installation code in Canada or the c...

Страница 8: ...arter pipe SK 18 may have to be cut to length depending on the wall thickness and or rear clearance of the stove Measure the wall thickness from the finished trim collar surface to the exterior mounti...

Страница 9: ...f the wall thimble with the screws provided 6 Attach the coaxial 45 elbow LB 45 to the unit Slide the 5 inch inner elbow pipe 1 inch over top of the collar and secure with three sheet metal screws Sea...

Страница 10: ...10 Fig 11...

Страница 11: ...components per the pre planned system configuration Support spacer must be used for each 6 feet of vertical and horizontal run The spacers are placed around the pipe and nailed or screwed to the fram...

Страница 12: ...nt pipe Attach backing plate to the outside wall with screws at each corner Fasten the vent pipe in place with sheet metal screws through the holes provided in the collar 2 Attach vent terminal box to...

Страница 13: ...t side facing rear and bark side forward 2 Place the front log on the tabs located at the front of the burner The log is notched to fit over top of the pilot 3 The top Y log bridges across from the fr...

Страница 14: ...ions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL...

Страница 15: ...ly depress and turn gas control knob clockwise past PILOT to OFF position DO NOT FORCE NOTE The SIT control has an interlock device which does not allow the pilot to be lit when the appliance is at op...

Страница 16: ...MFSD 1583_ _ 9 FRONT TRIM 2 pc required 1548 03 10 GLASS FRAME MFSD 1518 11 GLASS PANEL 2073 12 BURNER ASSEMBLY MFSD 1510 13 FLAME SHIELD MFSD 1564 14a PEDESTAL SIDE RIGHT 1545 5 14b PEDESTAL SIDE LE...

Страница 17: ...17 Fig 20...

Страница 18: ...18 NOTES...

Страница 19: ...local se conformer la norme CAN CGA B149 en vigueur MANUFACTURED MOBILE HOME FABRIQUEZ MOBILE MAISON May be installed in Manufactured Homes after the first sale See Instructions Pouvez tre install s d...

Страница 20: ...20 Pacific Energy Fireplace Products Ltd Box 1060 Duncan B C V9L 3Y2 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada...

Отзывы: