xiv.
Zoom in and align using the 3 axis adjustments until the component
fills the screen and is aligned. (Figures 5 & 18)
Figure 18
xv.
Push camera in until the screen changes.
xvi.
Mouse click on the green button, “Place” to lower the component.
(Figure 19)
Figure 19
xvii.
Mouse click on the green button again, “Start.”
xviii.
Allow the PCB to cool and remove.
b. Component removal – Note: If at any time you need to abort the process mouse
click on the Red Home button.
i. Conduct steps i – v in paragraph 6a.
ii. Position the board so the red laser sighting light is roughly in the center
of the component. To move the board forward and back simply move
the PCB in the arms. To move the assembly left and right push the
release handle away from you and move the assembly. Pull the release
handle towards you to secure the assembly. (Figure 20)
Nozzle on board
ready to start
heating
Rotate
Left and Right
Forward and Back