©2022 PACE Inc., Vass, North Carolina, All Rights Reserved Page 12
AutoOff
When enabled, after the unit has entered Temperature
SetBack, the AutoOff feature will turn off power to the
handpieces once a predetermined amount of time
(between 10- 90 minutes set by the user). When the
system has entered Temperature Setback, an internal
timer will start counting down.
If any key is pressed during the AutoOff timer countdown, the AutoOff and Setback timers will reset. The system
will return to normal operation. When/if the AutoOff timer reaches the end, the system will enter Auto Off. Power is
turned off to the heater and the display will show “SDN” meaning the iron has been Set Down for an extended
period and is turned off.
Exiting Auto Off
: To exit the AutoOff, first press and release the Scroll Up or Scroll
Down keys (
), then use the Program Key ( ) to advance through the channels and again press the Scroll Up
or Scroll Down keys (
) to wake up the selected channel. Alternatively turning the Power Switch OFF (“0”) and
then back ON (“1”) will reset all three channels back to normal operation.
9.
The display will show “Set AutoOff Time” and the current value as "Time = XX minutes" where XX can be
any value from 0 to 90 in increments of 1 minute. A time of "0" will disable the AutoOff feature completely.
Choose one of the following:
•
Press and release the Program Key ( ) to keep the currently stored Auto Off time.
•
Adjust the Auto Off value using the keypad (
).
•
Press and release the Program Key ( ) to proceed to the next step.
SetBack Temperature
The temperature that the irons will cool down to once they
entered into SetBack, can be adjusted.
10.
The display will show “Set Setback Temp” and
underneath will be the current setting. The default
value for this being 177°C (350°F) and
can be set
anywhere between 150°C (300°F) and 230°C (450°F).
•
Press and release the Program Key ( ) to keep the currently stored Instant SetBack temperature, or;
•
Adjust the stored Instant Setback Timer value using keypad. (
)
•
Press and release the Program Key ( ) to proceed to the next step.
Temperature Match Offset Control Mode
11.
The display screen will show “Set Offset Mode”
and “OS Mode =” and a number representing the
current mode. Select the OS Mode using keypad
(
) to choose one of the following;
a.
“OS Mode 1” (Offset Mode 1)
Offset will clear
to zero, which also clears the indicator dot, if
the handpiece
or
the tip is removed from the system. This is the default setting from the factory.
•
This option may be a good choice when using a variety of different tips or handpiece which
require the system to be calibrated after each change
b.
“OS Mode 2” (Offset Mode 2)
Offset will clear to zero if the handpiece is removed from the system,
but only removing the tip will keep the current offset and the indicator dot will begin BLINKING. A