©2022 PACE Inc., Vass, North Carolina, All Rights Reserved Page 9
SensaTemp Temperature Offset
To access the menu for changing the temperature offset for SensaTemp tools, hold the Program Key ( ) down
for 5 seconds. The display will change to show “Set Offset Chan 1 = 000”. Pressing the Program Key ( ) will
change this to “Set Offset Chan 2 = 000”. Pressing the Program Key ( ) one more time will change this to “Set
Offset Chan 3 = 000”, where we can adjust the actual temperature of the tip upwards a maximum of 150ºF. Use
the keypad (
) to increase or decrease the temperature offset. When finished press the Program Key ( ) to
return to normal operation or, after 5 seconds of inactivity, the system will return to normal operation on its own.
The value for Channel 1 or 2 cannot be altered here as those are AccuDrive channels, refer to 11b under
“Customizing Your System” for more details.
Factory Settings
The MBT360 system is equipped with several features which may be adjusted by the user. Listed below are the
default settings of each. To change and/or learn about any of these features, refer to the “Customizing Your
System” section of this manual.
Feature
Factory Setting
Feature
Factory Setting
Password
None Entered
Auto Off Timer
60 minutes
Default Temperature
Scale (°C/°F)
°F for 115 VAC Systems
SetBack Temperature
177°C (350°F)
°C for 230 VAC Systems
Temperature Match Mode
OS Mode = 1
“HI” Temperature Limit
427 °C (800 °F)
Set LCD Contrast
50
“LO” Temperature Limit
260 °C (500 °F)
Set LED Backlite
75
SetBack Timer
30 minutes
Set Temperature
371°C (700°F)
SetBack Reset
Sel
ect (instead of all)
Temperature Match Value
“0”
Customizing Your System
The menu driven user interface allows you to easily customize your system. In Set-Up Mode, you can:
•
Enter, remove, or change a Password.
•
Set the Default Temperature scale to °F or °C.
•
Change the Upper and Lower Temperature limits.
•
Enable or disable the Temperature Setback feature and adjust the time-out period (if enabled).
•
Enable or disable the Auto Off feature and adjust the time-out period (if enabled).
•
Adjust the temperature that the system goes to during Temperature SetBack.
•
Change how the Temperature Match is stored or cleared.
•
Manipulate the backlight and contrast of the LCD display for best visibility.
Entering Set-Up Mode
The following instructions should be performed to familiarize the operator with the system. Note: No settings will
be changed/saved until the end. If the unit is turned off before reaching the end, nothing will be changed.
1.
Place Power Switch in the “OFF” (“0”) position.
2.
Press and hold the Program Key ( ) while turning the Power Switch on (“I” position). Release all keys
when the software version is displayed.
Password
A password can be used to secure the Set-up Menu from
unauthorized access.