©2018 PACE Inc., Vass, North Carolina, All Rights Reserved                                                           Page 10 
 

 

Power Source 

 

Most malfunctions are simple and easy to correct. 
 

Symptom

 

Probable Cause

 

Solution

 

No power to 
system 

Blown Fuse 

Replace the fuse (located in the AC Receptacle Fuse 
Holder) with one of the same rated value. 

Defective Tip-Heater Cartridge 

Refer to the appropriate handpiece manual 

Handpiece will 
not heat 

Power Source Malfunction 

Contact PACE 

 
 

Spare Parts 

 
 

Description

 

PACE Part Number

 

Fuse 1.25 Amp, Time Lag (for 115V) 

1159-0251-P5 

Fuse 0.63 Amp, Time Lag (for 230V) 

1159-0214-P5 

Optional under shelf mounting bracket 

1321-0609-P1 

 

 

Содержание ADS200

Страница 1: ...0589 Rev Date 4 1232018 This manual applies to Model Firmware Revision Required Power Part Number ADS200 w Standard Tool Stand 1 2 120 VAC 8007 0578 ADS200 w ISB Tool Stand 1 2 120 VAC 8007 0579 ADS20...

Страница 2: ...LED Display Normal Operation 5 Digital Display Temperature Adjust Mode 5 Default Factory Settings 5 Customizing Your System 6 Entering Set Up Mode 6 Password 6 Temperature Scale 6 Temperature Limits 7...

Страница 3: ...uirements For 230V systems 197 253 VAC at 50 60 Hz Output Power 120 Watts Maximum Output Dimensions 104 mm H x 130 mm W x 152 mm D 4 1 H x 5 1 W X 6 D Weight 2 3 kg 5 lbs RoHS Compliant Yes Control Te...

Страница 4: ...to cool before storing 4 Always use PACE systems in a well ventilated area Fume extraction systems such as those available from PACE are highly recommended to help protect personnel from solder flux...

Страница 5: ...the Power Receptacle in the following manner 1 Align guide on connector with slot on power receptacle 2 Insert connector into power receptacle 3 Turn the connector housing clockwise to lock in place...

Страница 6: ...which will be 260 460 C 500 800 F as set at the factory If the upper limit has been reached the display will read HiL if the Lo limit is reached the display will read OFF Temperature limits can be adj...

Страница 7: ...ing when adjusting the desired Set Tip Temperature 1 The Set Tip Temperature 2 HiL High Temperature Limit when adjusting the set tip temperature and the maximum allowable temperature is exceeded Refer...

Страница 8: ...version is displayed Password 3 The LED Display will show the version of the microprocessor and change to read P or EP If the display reads EP a Password has been stored in system memory The password...

Страница 9: ...hese limits control how high or low the Set Temperature can be adjusted to during normal operation Automatic Setback Timer What is Temperature Setback To preserve tip life and save energy the system c...

Страница 10: ...lue between 015 and 240 representing seconds This indicates how long of a delay before the system goes into SetBack mode when the handpiece is placed into the Instant SetBack Tool Stand if one is atta...

Страница 11: ...ng Set Up Mode 13 The LED Display now reads End The Set Up Mode procedure is now complete Choose one of the following steps Press and release the Scroll Up Key to save the changes exit the Set Up Menu...

Страница 12: ...e fuse located in the AC Receptacle Fuse Holder with one of the same rated value Defective Tip HeaterCartridge Refer to the appropriate handpiece manual Handpiece will not heat Power Source Malfunctio...

Страница 13: ...est widest tip with the maximum contact surface area with which you can safely access the work Standard Tips For delicate micro soldering to challenging high thermal mass applications Ultra Performanc...

Страница 14: ...ng equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED BY APPLICABLE LAW SELLER WILL HAVE NO OTHER OBLIGATION WITH REGARD TO ANY...

Отзывы: