background image

19

 

MAINTENANCE

 

4.

Both the rocker arms should be loose at TDC on
the compression stroke. If they are not, rotate the
engine 360°.

5.

Insert a feeler gauge between the rocker arm and
the push rod and check for clearance (see Figure
21). See table below for valve lash specifications

Figure 21

 

(1) Push Rod, (2) Feeler Gauge Area

(3) Rocker Arm, (4) Jam Nut, (5) Adjusting Nut

Standard Valve Lash

 

6.

If an adjustment is required, hold the adjusting nut
and loosen the jam nut.

7.

Turn the adjusting nut to obtain the correct valve
lash. When the valve lash is correct, hold the
adjusting nut and tighten the jam nut to 106 in-lb
(12 Nm).

8.

Recheck the valve lash after tightening the jam nut.

9.

Perform this procedure for both the intake and
exhaust valves.

10. Install the rocker arm cover, gasket and spark  plug.

CLEANING THE INVERTER

 

It is important to inspect and clean the inverter before 
every use.

 

Clean All Engine Air Inlet and Outlet Ports 

– Make 

sure all engine air inlet and outlet ports are clean of any 
dirt and debris to ensure the engine does not run hot.

 

BATTERY SERVICE

 

To ensure the battery remains charged, the generator 
should be started every 2 to 3 months and run for a 
minimum of 15 minutes or a charger should be plugged 
into the generator and the generator should be charged 
overnight. Plug the cord from the charger into the 
charging port 

” on the generator. Plug the charger into 

a 220-volt AC outlet.

 

Battery Replacement

 

1.

Remove the spark plug wire from spark plug.

2.

Loosen the rubber strap holding the battery in
place.

3.

Disconnect the black negative (-) battery cable from
the battery first.

4.

Disconnect the red positive (+) battery cable
second and remove the battery.

NOTICE

 

Dispose of the used battery properly according to 
the guidelines established by your local or state 
government.

 

5.

Install the new battery into the generator frame.

6.

Connect the red positive (+) battery cable to the
battery first.

7.

Connect the black negative (-) battery cable to the
battery second.

8.

Replace rubber strap to hold battery in place.

9.

Install the spark plug wire onto spark plug.

Seebelowfor thebatteryspecification

 

when replacing the battery.

 

After Market Battery 
Model

 

YT5AL

 

Volts

 

12

 

Amp Hr

 

5

 

Dimensions

 

4.63 in by 2.38 in by 5 in

 

1

 

2

 

3

 

4

 

5

 

Intake Valve

 

Exhaust Valve

 

Valve Lash

 

0.0035 ± 0.0043 in

 

(0.09 ± 0.11 mm)

 

0.0043 ± 0.0051 in

 

(0.11 ± 0.13 mm)

 

Bolt Torque

 

8-12N.m

8-12N.m

Содержание P4000i

Страница 1: ...FOR YOUR SAFETY You must read and understand this manual before use Keep this manual for future reference...

Страница 2: ...initions 3 Safety Symbol Definitions 3 General Safety Rules 4 ASSEMBLY 5 Hooking Up the Battery 5 FEATURES 6 Basic Inverter Features 6 Control Panel Features 7 OPERATION 8 Before Starting the Inverter...

Страница 3: ...llows the safety alerts symbol DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could res...

Страница 4: ...l ventilated area Never remove the fuel cap with the engine running Never refuel the inverter while the engine is running Always turn engine off and allow the generator to cool before refueling Only f...

Страница 5: ...nel on the back of the unit next to the muffler see Figure 1 2 Verify the positive battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 3 Caref...

Страница 6: ...maintenance MufflerandSparkArrestor Avoidcontact until the engine is cooled down The spark arrestor prevents sparks from exiting the muffler It must be removed for servicing Roller Board Wheels For ea...

Страница 7: ...ing 12 Volt automotive type batteries USB Duplex 5V DC USB outlets that come with 1 and 2 1 amp rating Parallel outlets Parallel outlets enable a user to run two generators simultaneously Ground Termi...

Страница 8: ...opper wire The wire connects to the terminal between the lock washer and nut Tighten the nut securely to ensure good connection Grounding the generator protects you from electric shock that results fr...

Страница 9: ...r only This table is intended for reference only The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are hig...

Страница 10: ...inverter is started and the engine gets warm it is not safe to add petrol to the fuel tank or engine oil to the engine while the engine is running or the en gine and muffler are hot CHECKING AND OR AD...

Страница 11: ...l the fuel cap by rotating clockwise Figure 5 Maximum Petrol Fill Level STARTING THE INVERTER BEFORE STARTING THE INVERTER REVIEW SAFETY SECTION STARTING ON PAGE 4 For proper starting and operation of...

Страница 12: ...nothing is plugged into any of the outlets 3 Make sure battery is connected see Hooking Up the Battery on page 6 4 Make sure the circuit breakers are properly set see Figure 6 5 Turn the Fuel Control...

Страница 13: ...hould be used only after the inverter has been warmed up to operating temperature 1 To turn on the efficiency mode press the switchto the ON position 2 If no load is present the inverter RPM will drop...

Страница 14: ...exposed skin with soap and water WARNING Failure to perform periodic maintenance or not following maintenance procedures can cause the inverter to malfunction and could result in death or serious inju...

Страница 15: ...lat level surface or an inaccurate reading may result causing serious engine damage ADDING ENGINE OIL 1 Always operate or maintain the inverter on a flat surface 2 Stop engine if running 3 Let engine...

Страница 16: ...arm water Slowly squeeze the foam to thoroughly clean NOTICE NEVER twist or tear the foam air filter element during cleaning or drying Only apply slow but firm squeezing action 6 Rinse in clean water...

Страница 17: ...ure 13 on page 16 4 Remove the spark plug cover by firmly pulling the metal spark plug boot handle directly away from the engine see Figure 18 Figure 18 Pull off Spark Plug Cover NOTICE Never apply an...

Страница 18: ...ler cover in place see Figure 20 4 Loosen the clamp holding the spark arrestor onto the muffler 5 Slide the spark arrestor band clamp off the spark arrestor screen Figure 20 Remove Muffler Access Pane...

Страница 19: ...ttery remains charged the generator should be started every 2 to 3 months and run for a minimum of 15 minutes or a charger should be plugged into the generator and the generator should be charged over...

Страница 20: ...on all petrol from the fuel tank as best as possible 3 Start the engine and allow the inverter to run until all the remaining petrol in the fuel lines and carburetor is consumed and the engine shuts o...

Страница 21: ...petrol to the inverter 2 Fuel flow is obstructed 2 Inspect and clean fuel delivery passages 3 Dirty air filter 3 Check and clean the air filter 4 Low oil level shutdown switch is preventing the unit...

Страница 22: ...ce with your local authority or recycling centre 5 Certain products contain batteries which should not be disposed of in your domestic waste 6 You MUST recycle batteries in accordance with your local...

Страница 23: ...ollowing CE Directives 97 68 EC Non Road Mobile Machinery Directive 2000 14 EC Outdoor Noise Directive 2004 108 EC Electro Magnetic Compatibility Device 2006 42 EC Machinery Directive 3 6kW OND 201650...

Страница 24: ...ed London Road Pembroke Dock Pembrokeshire SA72 4RW UK Telephone 44 0 1646 687880 Fax 44 0 01646 686198 Website www p1pe co uk To register your machine for the manufacturer s warranty please visit htt...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...P1PE Position One Power Equipment Isaac Way Pembroke Dock Pembrokeshire SA72 4RW www p1pe co uk...

Отзывы: