12
OPERATION
ELECTRIC START
1.
Check oil levels (see
Initial Oil Fill
on page 11)
2.
Make sure nothing is plugged into any of the
outlets.
3.
Make sure battery is connected (see
Hooking Up
the Battery
on page 6).
4.
Make sure the circuit breakers are properly set
.
5.
Turn the Fuel Control Switch to the
ON (RUN)
position
(see Figure 7).
Figure 7: Turn Fuel Switch to ON Position
6.
Push and hold the engine start push button for 1
second and release (see Figure 8). The engine will
automatically set the choke and begin the start
sequence.
Figure 8: Electric Start Button - PUSH
7.
Plug in electronic devices.
MANUAL START
1.
Check oil levels (see
Initial Oil Fill
on page 11)
2.
Make sure nothing is plugged into any of the
outlets.
3.
Make sure battery is connected (see
Hooking Up
the Battery
on page 6).
4.
Make sure the circuit breakers are properly set
(see Figure 6).
5.
Turn the Fuel Control Switch to the
ON (RUN)
position (see Figure 7).
6.
Firmly grasp and pull the recoil handle slowly until
you feel increased resistance. At this point, apply
a rapid pull while pulling out from the inverter (see
Figure 9).
Figure 9: Pull the Recoil Handle out from Inverter
7.
Plug in electronic devices.
WIRELESS REMOTE START (OPTIONAL)
1.
Check oil levels (see
Adding Engine Oil
page 11
)
2.
Battery must be connected for auto choke to work.
3.
Make sure the circuit breakers are properly set (see
Figure 6).
4.
Confirm that the Fuel Control Switch is in the
ON
position (see Figure 7).
5.
Push the
START
icon on the wireless remote. (see
Figure 10).
Figure 10: Wireless Remote - START
START
STOP