background image

15

 

MAINTENANCE

 

ENGINE OIL MAINTENANCE

 

Engine Oil Specification

 

1.

Only use the engine oil specified in Figure 12.

2.

Only use 4-stroke/cycle engine oil. 

NEVER USE

2-STROKE/CYCLE OIL

. Synthetic oil is an

acceptable substitute for conventional  oil.

Figure 12: Recommended Oil

 

CHECKING ENGINE OIL

 

NOTICE

 

Always maintain proper engine oil level. Failure to 
maintain proper engine oil level could result in severe 
damage to the engine and/or shorten the life of the 
engine.

 

Always use the specified engine oil. Failure to use the 
specified engine oil can cause accelerated wear and/ 
or shorten the life of the engine.

 

Engine oil level should be checked before every use.

 

1.

Always operate or maintain the inverter on a flat
surface.

2.

Stop engine if running.

3.

Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).

4.

Remove the oil service panel to access the oil fill/
drain plug (see Figure 3 on page 11).

5.

With a damp rag, clean around the oil fill/drain  plug.

6.

Remove the oil fill/drain plug.

7.

Check oil level: When checking the engine oil, remove
the oil fill/ drain plug (see Figure 4 on page 11).

• The oil level is acceptable if oil is visible at the

bottom of the threads of the oil fill  plug.

• If oil level is low, add to the correct level using

the supplied oil fill bottle. Do not overfill the oil
crankcase.

NOTICE

 

Engine oil must always be checked and added when 
the inverter is on a flat, level surface, or an inaccurate 
reading may result, causing serious engine damage.

 

ADDING ENGINE OIL

 

1.

Always operate or maintain the inverter on a flat
surface.

2.

Stop engine if running.

3.

Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).

4.

Remove the engine service panel to gain access to
the oil fill/drain plug.

5.

Thoroughly clean around the oil fill/drain plug.

6.

Remove the oil fill/drain plug.

7.

Select the proper engine oil as specified in Figure 12.

8.

Using the supplied oil funnel, slowly add engine oil
to the engine. Stop frequently to check the oil level
and avoid overfilling.

CHANGING ENGINE OIL

 

1.

Stop the engine.

2.

Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).

3.

Remove the oil service panel to gain access to the
oil fill/drain plug.

4.

Place oil pan (or suitable container) under the oil fill/
drain plug.

5.

Remove oil fill/drain plug. With a damp rag, thor- 
oughly clean around the oil fill/drain plug.

6.

Insert provided funnel around oil fill/drain and
carefully tilt the inverter so the oil drains down the
through the funnel into the container.

7.

Allow oil to completely drain.

8.

Fill crankcase with oil following the steps outlined  in

Adding Engine Oil 

above and tighten oil plug.

9.

Dispose of used engine oil  properly.

NOTICE

 

Never dispose of used engine oil by dumping the 
oil into a sewer, on the ground, or into groundwater 
or waterways. Always be environmentally 
responsible. Follow the guidelines of the 
governmental agencies for proper disposal of 
hazardous materials. Consult local authorities or 
reclamation facility.

 

Содержание P4000i

Страница 1: ...FOR YOUR SAFETY You must read and understand this manual before use Keep this manual for future reference...

Страница 2: ...initions 3 Safety Symbol Definitions 3 General Safety Rules 4 ASSEMBLY 5 Hooking Up the Battery 5 FEATURES 6 Basic Inverter Features 6 Control Panel Features 7 OPERATION 8 Before Starting the Inverter...

Страница 3: ...llows the safety alerts symbol DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could res...

Страница 4: ...l ventilated area Never remove the fuel cap with the engine running Never refuel the inverter while the engine is running Always turn engine off and allow the generator to cool before refueling Only f...

Страница 5: ...nel on the back of the unit next to the muffler see Figure 1 2 Verify the positive battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 3 Caref...

Страница 6: ...maintenance MufflerandSparkArrestor Avoidcontact until the engine is cooled down The spark arrestor prevents sparks from exiting the muffler It must be removed for servicing Roller Board Wheels For ea...

Страница 7: ...ing 12 Volt automotive type batteries USB Duplex 5V DC USB outlets that come with 1 and 2 1 amp rating Parallel outlets Parallel outlets enable a user to run two generators simultaneously Ground Termi...

Страница 8: ...opper wire The wire connects to the terminal between the lock washer and nut Tighten the nut securely to ensure good connection Grounding the generator protects you from electric shock that results fr...

Страница 9: ...r only This table is intended for reference only The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are hig...

Страница 10: ...inverter is started and the engine gets warm it is not safe to add petrol to the fuel tank or engine oil to the engine while the engine is running or the en gine and muffler are hot CHECKING AND OR AD...

Страница 11: ...l the fuel cap by rotating clockwise Figure 5 Maximum Petrol Fill Level STARTING THE INVERTER BEFORE STARTING THE INVERTER REVIEW SAFETY SECTION STARTING ON PAGE 4 For proper starting and operation of...

Страница 12: ...nothing is plugged into any of the outlets 3 Make sure battery is connected see Hooking Up the Battery on page 6 4 Make sure the circuit breakers are properly set see Figure 6 5 Turn the Fuel Control...

Страница 13: ...hould be used only after the inverter has been warmed up to operating temperature 1 To turn on the efficiency mode press the switchto the ON position 2 If no load is present the inverter RPM will drop...

Страница 14: ...exposed skin with soap and water WARNING Failure to perform periodic maintenance or not following maintenance procedures can cause the inverter to malfunction and could result in death or serious inju...

Страница 15: ...lat level surface or an inaccurate reading may result causing serious engine damage ADDING ENGINE OIL 1 Always operate or maintain the inverter on a flat surface 2 Stop engine if running 3 Let engine...

Страница 16: ...arm water Slowly squeeze the foam to thoroughly clean NOTICE NEVER twist or tear the foam air filter element during cleaning or drying Only apply slow but firm squeezing action 6 Rinse in clean water...

Страница 17: ...ure 13 on page 16 4 Remove the spark plug cover by firmly pulling the metal spark plug boot handle directly away from the engine see Figure 18 Figure 18 Pull off Spark Plug Cover NOTICE Never apply an...

Страница 18: ...ler cover in place see Figure 20 4 Loosen the clamp holding the spark arrestor onto the muffler 5 Slide the spark arrestor band clamp off the spark arrestor screen Figure 20 Remove Muffler Access Pane...

Страница 19: ...ttery remains charged the generator should be started every 2 to 3 months and run for a minimum of 15 minutes or a charger should be plugged into the generator and the generator should be charged over...

Страница 20: ...on all petrol from the fuel tank as best as possible 3 Start the engine and allow the inverter to run until all the remaining petrol in the fuel lines and carburetor is consumed and the engine shuts o...

Страница 21: ...petrol to the inverter 2 Fuel flow is obstructed 2 Inspect and clean fuel delivery passages 3 Dirty air filter 3 Check and clean the air filter 4 Low oil level shutdown switch is preventing the unit...

Страница 22: ...ce with your local authority or recycling centre 5 Certain products contain batteries which should not be disposed of in your domestic waste 6 You MUST recycle batteries in accordance with your local...

Страница 23: ...ollowing CE Directives 97 68 EC Non Road Mobile Machinery Directive 2000 14 EC Outdoor Noise Directive 2004 108 EC Electro Magnetic Compatibility Device 2006 42 EC Machinery Directive 3 6kW OND 201650...

Страница 24: ...ed London Road Pembroke Dock Pembrokeshire SA72 4RW UK Telephone 44 0 1646 687880 Fax 44 0 01646 686198 Website www p1pe co uk To register your machine for the manufacturer s warranty please visit htt...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...P1PE Position One Power Equipment Isaac Way Pembroke Dock Pembrokeshire SA72 4RW www p1pe co uk...

Отзывы: