Checklist for periodic inspection
Check point
Approval
criteria
If not
approved
Date Comments/initials
Bolts, nuts
(Check for
loose and
missing parts).
Inspection
method
Visual check and
mechanical
Tighten
Bolts etc., must
be tightened.
Hitch, gear,
bearings,
chain stop,
chain and
hook.
(Check for
wear, rust and
damage).
Inspection
method
Visual check and
mechanical
Replace any
damaged
parts
No visible
defects or
damage.
Chain guide
(Check for wear
or damage to
the pulley.
Check for wear
or burring
where the
chain enters
the hoist).
Inspection
method
Visual check and
mechanical
Replace any
damaged
parts
No visible
defects or
damage.
Brake parts
(Check for signs
of wear on
brake parts).
Inspection
method
Visual check and
mechanical
Replace any
damaged
parts
No visible
defects or
damage.
Control unit
(Check the
buttons on the
control unit).
Inspection
method
Visual check and
functional.
Replace the
control unit.
Must function
and flip back
when released
Cables
(Check the
power cable,
control cables
and control
unit).
Check method
Visual
Replace
damaged
parts – must
be done by
a qualified
electrician.
No damage to