loss of carD:
Anyone finding a lost card thus has authorization to use
it at the corresponding charging pillar. So please advise your customers
to be prudent. In the event of loss, your customer will require a new card.
Lost cards, however, cannot be blocked on the HTML page.
•
error: invaliD configuration:
In this case please log into the
HTML page as Administrator and configure your EWS Box under menu
item "Installations", according to your required parameters. Under menu
item "Maximum current (A)" enter the applicable Current Value for your
system and save this to the settings.
•
error: ventilation not supporteD:
Here the ventilation system
you use is not supported by the EWS Box. In such case, please change the
ventilation system. It could, however, be the case that the respective ven-
tilation system is not yet activated in the settings on the HTML page. Log
in to the HTML page as Administrator and change the setting "System pa-
rameter - Ventilation" under menu item "Installations". Otherwise check
connection of the ventilator contactor in the contactor terminal X102.
•
error: locking/unlocking mechanism:
In this case, please check
the connection to the socket actuator. The plug may have been incor-
rectly inserted in the bushing/port or the connection of the locking de-
vice to the EWS Box pins may not be correct. In this case, please contact
your service partner.
•
error: activate contactor:
Here there is a faulty contact in the
EWS Box in the contactor terminal X102 at contactor EV 1 or contactor
EV 2. It may be necessary to disconnect and reconnect these. It might
also be possible that the charging contactor feedback signal to the X401
connection for EV 1 and X402 for EV 2 are failing due to an incorrect con-
nection / contact at the Pins 15.
•
error: charging interrupteD (meter):
This error is displayed if,
for example, the S0+ or S0 output of the meter has no or an incorrect
contact. Please check your plug connection at the meter and also at
Pins 4 or 10 at connections X401 / X402. Otherwise, please contact your
service partner.
•
charging connection rcD / outage rcD sWitch:
Remove plug
from the charging socket and re-insert the RCD. Plug the cable back into
the socket.
•
error: current value cable / interrupteD charging cable:
Either a cable which is incompatible with this charging station has been
used with an incorrect resistance code or the cable is defect. Replace the
charging cable with a correct / functioning cable.
•
in the event of other errors:
In each case, please restart the Wall-
box by switching off all RCCBs and the main switch and on again after
approx. 30 seconds.
Please reference the exact positions at the EWS Box in the EWS-Box
Quick guide to operations / HTML configuration which is available for
download from the Schletter GmbH website; see corresponding link in
„10. Links for support“
.