AIO-OZONE Installation & Programming Guide

Periodic cleaning of the CD cell within your Ozotech  

product is important and will keep your generator 

operating effectively and efficiently. Cleaning the cell can 

be done quickly…in six easy steps. 

Disconnect Power 

Supply from wall outlet.

Step 1:

 Remove the cell from the unit by snipping the 

zip-tie, 

Photo 1.

EOG CD Cell Cleaning Process

Photo 1

Photo 2

Photo 3

Photo 4

Photo 5

Step 2:

 

Remove the cell from the metal clips, 

Photo 2.

Step 3:

 

Disconnect the wire connection on the bottom of 

the cell, 

Photo 3.

Step 4:

 Pull the Tygon tubing from the cell itself  

Photo 4-5.

Содержание AIO3 Systems

Страница 1: ...AIO3 Ozone Installation Programming Guide AIO3 Systems with Enhanced Oxidation Generator...

Страница 2: ...ONE OZOTECH KIT Comes installed on system AIO3 OZONE OZOTECH FIELD KIT Dealer install kit No integrated power supply jack Nelsen EOG AIO3 OZONE NELSEN KIT Comes installed on system AIO3 OZONE NELSEN F...

Страница 3: ...Tabs Forefingers Here Photo A Photo B Photo C Step 4 For the Nelsen EOG Model Reference 2 on previ ous page disconnect the power supply from the control board Photo C Step 5 Unsnap the top of the driv...

Страница 4: ...and replace Brine Fitting Photos F G H Step 6 If you have not already done so Unsnap the top of the drive bracket using your thumbs and forefingers to expose the backplate Photo E Photo E Thumbs Push...

Страница 5: ...hoto O Installation of EOG Unit continued Step 10 Attach the tubing to connection where inlet screen and short gray tube was removed Photo L Step 11 At this point if you are using the Optional Integra...

Страница 6: ...ly to the control board if not already connected as when using Ozotech Model Photo Q Step 15 Both the gray wire and power supply must fit into the wire chases Snap the bracket back into place Do Not P...

Страница 7: ...ote Holding reset for 3 seconds will change pulsing green LED to solid green if the cell is in good operating order If LED changes to solid red the cell needs cleaned Photo 2 Photo 1 Step 17 For Nelse...

Страница 8: ...TODAY NORMAL GAL MIN x1000 NOR CAPACITY FILL REMAINING PAM Use UP or DOWN to set REGEN to OFF Press NEXT to go to Step 9 Press REGEN to return to previous step Step 8 CLOCK NEXT UP DOWN REGEN TIME SE...

Страница 9: ...UP or DOWN to set RELAY 1 to 15 Press NEXT to go to Step 11 Press REGEN to return to previous step Step 11 indicates the length of time the EOG unit is activated Use UP or DOWN to adjust the amount o...

Страница 10: ...can be done quickly in six easy steps Disconnect Power Supply from wall outlet Step 1 Remove the cell from the unit by snipping the zip tie Photo 1 EOG CD Cell Cleaning Process Photo 1 Photo 2 Photo...

Страница 11: ...RNING DO NOT install the EOG unit on any other control valve other than specialty Clack based controls Internal components may not be compatible with Ozone CAUTION When re installing electronic contro...

Страница 12: ...AIO INTEGRATED OZONE Installation Programming Guide Part AIO3 OZONE PROGRAM GUIDE...

Отзывы: