-5-

AIO-OZONE Installation & Programming Guide

Power Supply Jack

Power Supply Jack

for Control Valve

Installation of EOG Unit continued

EOG Unit Indicator Light- 

Photo 1

Green Light Blinking Slowly - Standby mode
Green Light Blinking Quickly - High voltage startup
Green Light Solid - High voltage is ON & stable; CD cell 

producing ozone
Red Light Solid - Unstable high voltage; CD cell may 

need cleaned
Green/Red Light Alternating Twice/Second - HV is ON, 

but current is low
Red Light Flashing - NO or NC contacts are shorted
Orange Light - 1 year timer has expired; clean CD cell, 

then push reset button to reset timer 

Photo 2.

Note:

 Holding reset for 3 seconds will change pulsing 

green LED to solid green if the cell is in good operating 

order. If LED changes to solid red, the cell needs cleaned.

Photo 2

Photo 1

Step 17:

 For Nelsen Unit using the integrated power sup-

ply cord connect the control valve power supply cord to 

the power supply jack. Plug in the EOG to the wall outlet.
Once you power either system, the pulsing green LED 

may turn to pulsing orange. Pressing the reset button will 

reset it to pulsing green.

Nelsen EOG Model

At this point installation of your Enhanced Oxidation Gen-

erator is complete. Continue to page 8 for programming 

instructions.

Flashing Green/Red means that the circuit is looking for 

an optimum frequency to operate within. It is still making 

ozone in the mode and will eventually go to solid green  

or red.

Содержание AIO3 Systems

Страница 1: ...AIO3 Ozone Installation Programming Guide AIO3 Systems with Enhanced Oxidation Generator...

Страница 2: ...ONE OZOTECH KIT Comes installed on system AIO3 OZONE OZOTECH FIELD KIT Dealer install kit No integrated power supply jack Nelsen EOG AIO3 OZONE NELSEN KIT Comes installed on system AIO3 OZONE NELSEN F...

Страница 3: ...Tabs Forefingers Here Photo A Photo B Photo C Step 4 For the Nelsen EOG Model Reference 2 on previ ous page disconnect the power supply from the control board Photo C Step 5 Unsnap the top of the driv...

Страница 4: ...and replace Brine Fitting Photos F G H Step 6 If you have not already done so Unsnap the top of the drive bracket using your thumbs and forefingers to expose the backplate Photo E Photo E Thumbs Push...

Страница 5: ...hoto O Installation of EOG Unit continued Step 10 Attach the tubing to connection where inlet screen and short gray tube was removed Photo L Step 11 At this point if you are using the Optional Integra...

Страница 6: ...ly to the control board if not already connected as when using Ozotech Model Photo Q Step 15 Both the gray wire and power supply must fit into the wire chases Snap the bracket back into place Do Not P...

Страница 7: ...ote Holding reset for 3 seconds will change pulsing green LED to solid green if the cell is in good operating order If LED changes to solid red the cell needs cleaned Photo 2 Photo 1 Step 17 For Nelse...

Страница 8: ...TODAY NORMAL GAL MIN x1000 NOR CAPACITY FILL REMAINING PAM Use UP or DOWN to set REGEN to OFF Press NEXT to go to Step 9 Press REGEN to return to previous step Step 8 CLOCK NEXT UP DOWN REGEN TIME SE...

Страница 9: ...UP or DOWN to set RELAY 1 to 15 Press NEXT to go to Step 11 Press REGEN to return to previous step Step 11 indicates the length of time the EOG unit is activated Use UP or DOWN to adjust the amount o...

Страница 10: ...can be done quickly in six easy steps Disconnect Power Supply from wall outlet Step 1 Remove the cell from the unit by snipping the zip tie Photo 1 EOG CD Cell Cleaning Process Photo 1 Photo 2 Photo...

Страница 11: ...RNING DO NOT install the EOG unit on any other control valve other than specialty Clack based controls Internal components may not be compatible with Ozone CAUTION When re installing electronic contro...

Страница 12: ...AIO INTEGRATED OZONE Installation Programming Guide Part AIO3 OZONE PROGRAM GUIDE...

Отзывы: