47
082809
OVSOL System 5-16-SCE
/ 80 gallon, Evacuated tube, Single coil electric tank
System Assembly
Installing OVSOL System 5-16-SCE
Model Number 540 00 16K-SCE
Solar Closed-Loop Domestic Hot Water System
Oventrop Components
OVSOL 5 -16 Evacuated Tube Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
filled weight: 225 lbs.
Regusol 130 EL Solar Transmission Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
filled weight: 20 lbs.
80 Gallon OVSOL glass lined Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
filled weight: 920 lbs.
Regusol Fill and Flush Valve
Oventrop NT Propelyne Glycol Antifreeze
System Design Description
The solar closed-loop heating system consists of the Oventrop Regusol 130 EL pump and control station,
one OV-5 evacuated tube collector, and an 80 gallon glass lined tank with one internal coil and electric backup ele-
ment. An expansion tank is installed at the Regusol on the safety group. Oventrop NT propelyne glycol antifreeze is
filled into the closed loop system through the Regusol fill and flush valve.
Cold water is piped to the solar tank. An anti-scald valve must be installed for hot water mixing to hot water
fixtures if the solar tank high limit in the Regusol controller is set above 120
o
F.