Страница 2: ...f all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequ...

Страница 3: ...allation 2 3 1 Mounting 2 3 2 Orientation 4 4 Maintenance 5 5 Power Considerations 5 5 1 Solar Power and Lead Acid Batteries 5 5 2 Voltage Regulator 6 Appendix A Solar Panel Connector A 1 Figures 1 So...

Страница 4: ...This is a blank page...

Страница 5: ...s marked SOLAR PANEL located underneath the 700X Control Module An external Gel Cell or AGM lead acid battery can be connected to the CR7 at the terminals marked EXTERNAL BATTERY next to the SOLAR PAN...

Страница 6: ...outh if located in the Northern Hemisphere or facing north in the Southern Hemisphere The solar panel mounts to the mast or leg of a tripod or any 1 5 8 schedule 40 pipe see Figure 1 The panel should...

Страница 7: ...LEG ALTERNATE POSITION SOLAR PANEL ON MAST 015 PYRANOMETER MOUNTING ARM GILL RADIATION SHIELD DATALOGGER ENCLOSURE FIGURE 1 Solar Panel Mounting RF MODEM RADIO MSX10R DATALOGGER 12 V BATTERY FIGURE 2...

Страница 8: ...re given in Table 1 After determining the tilt angle loosen the 5 16 nuts on each side of the solar panel adjust the panel and tighten the two nuts to secure the position See Figure 4 TABLE 1 Solar Pa...

Страница 9: ...ked by measuring the voltage output Check the voltage with a voltmeter connected between the two leads of the solar panel There must be solar radiation incident on the panel and there must be a load c...

Страница 10: ...ing used by the system The battery must have enough capacity to power the system during times of no charging night or low charging stormy winter days 5 2 Voltage Regulator The solar panel must be regu...