B-144-12-E
30
Parameter
Code
Default Setting
Description
Remarks
1 or 50
"An item shown on
parameter label"
Not a parameter
to be set up
Not a parameter
to be set up
Factored pulse output
"ON" width
(Unit: [msec])
Furnishes a 1Hz
simulated factored pulse
output irrespective of
flowmetering.
Furnishes a 10Hz
simulated factored pulse
output irrespective of
flowmetering.
Ex.: To change pulse width from 1ms
to 50ms
→
Set to "Pon 50" (msec).
(Note 4)
●
This function is useful in loop check,
etc.
●
For operation in practice, see
"About Dummy Output Functions
(special features),"
Pon
Pd1
Pd2
Pulse width
Pulse
dummy
output 1
Pulse
dummy
output 2
NOTES 1. When conversion factor (H) has been set, change pulse weight (Pu), indicated unit (Un), etc. must be changed relative to
the units after conversion.
F
×
H
2. Be sure to set up a value such that
< Pu < F
×
H
×
10000.
2
3. Not shown on the LCD if the meter operates on the battery alone.
4. Be sure to set a value such that factored pulse "OFF" width > 1 ms.
※
For the factory -set parameters, refer to Dsfault Parameter Settings supplied with the product.