8.1.2 Error Output Selection
Menu Item
Error Name
Description
Saturated alarm
Saturated output alarm
When analog output is out of 2.4mA or 21.6mA range
or pulse output is above 11kHz.
Sensor failure
Sensor alarm
When input from the sensor (drive, temperature) is
out of range, or result of measurement (flowrate,
density) is out of permissible range.
Transmitter failure
Transmitter alarm
An error in data processing inside the transmitter.
Parameter alarm
Parameter alarm
Parameter established is out of range.
Adjustment failure
Zeroing error
Zeroing error (above max. allowable range ± 10%)
Slug flow alarm
Slug flow alarm
Out of predetermined density range, such as bubble
entrapment (default: 0.3 to 2gmL)
Fixed output
Fixed output
Analog output, pulse output, status output, etc. are
fixed.
Calibration in
Calibration in progress
Calibration is in progress (including zeroing).
progress
Burst mode
Burst mode enabled
Currently in the burst mode.
NOTES 1. Error output is valid only when“Error Status”is selected at Status Output menu.
2. Error output is selectable at Error Select menu (menu items turned“ON”become valid).
3. When one or more of the selected menu items happen to be in error, the contact-closure output
becomes “OFF” (normally“ON”).