EXAMPLE :
25 CODE
39 CODE
Set bar code 39 specification as:
20 code, 6 centimeter, ratio of thick line &
thin line 3:1
ESC _ s 6l20n30R
Command:
ESC _sU1234567890AA@
Scan Output : 1234567890AA
Set bar code 100 dot height.
ESC r 100 V
Set bar code 25 specification as:
20 code, 6 centimeter, ratio of thick line & thin line 3:1
ESC _ r 6l20n30R
Command:
ESC _rU01234567890123@
Scan Output : 01234567890123
UPC_A CODE
EAN-13 CODE
Set EAN-13 4 dots for each module.
Bar data “1234567890123”
Command:
ESC _w4M1234567890123
Scan Output : 1234567890123
Set UPC_A 5 dots for each module.
Bar data “1234567890123”
Command:
ESC _t5M1234567890123
Scan Output : 1234567890123
EAN-8 CODE
Set EAN-8 3 dots for each
module.
Bar data “12345678”
Command:
ESC _x3M12345678
Scan Output : 12345678
Output
Technology
Printcenter
45
Users
Guide
81