Installation and Setup
Preparation
Required tools and accessories:
Screw driver (No.2 × 1)
Open Wrench for 20mm × 1
Related
manuals
Fanfold paper × 1(carton)
Caution, Power requirements
Supply correct power 220V±11%, Single phase, 3 wires 50/60HZ, 4.5KVA Supply two dedicated
“hots”(L1 and L2) and a safety/earth ground with both power legs fused for 30 A.
Use only UL/CSA compliant power cable.
Cable ratings:
Voltage
600V
Type
SO
Stranding
105x30 AWG
Temperature
60 C
Operational environment
Temperature 10 ~ 30
Humidity
30 ~ 80% RH
Inclination of floor less 1°
Standby noise level : 55dB
Operating noise level : 70 dB
Precautions:
1) Turn off the power and the circuit breaker before installing.
2)
Do not use the printer on carpet. The printer may not operate normally due to cotton fiber
and static electricity.
3)
Do not operate the printer near heating source, dusty locations, or direct sunlight.
4)
Do not place the printer on any unstable surfaces.
5)
Do not put the printer near combustibles.
6)
Install the printer in a well air-conditioned/ventilated room.
7)
Do not obstruct the ventilation slots on the front or rear of the printer. Excessive
temperature rise in the printer may cause abnormal printer operation.
8)
Be sure that the input voltage matches the applied AC voltage or it may cause equipment
to malfunction or cause personal injury.
Output Technology Printcenter 45 Users Guide