23
Cleaning the blower damper (
continued)
Maintenance
Apply high temperature caulk around
the blower plate, (500 Degree or
higher).
Apply high temperature grease
(500 Degree or higher) within
the pivoting parts of the hinge.
The grease acts as a barrier to
the stickiness of the creosote
and helps keep it out of the
hinged area.
Replace the blower plate to the
blower tube. Be sure that the flap-
per seats well against the blower
pate and swings freely. If not, the
hinge may have been bent during
the cleaning process. Remove and
carefully adjust the hinge.
Содержание Elite Heat 4868P
Страница 26: ...26 Wiring Diagram ...