Operational Procedures
Filling the furnace with water
STEP 1 : Remove float cap assembly to one
side of the float and vent tube.
STEP 2 : Insert a garden hose into the float
and vent tube. Be sure that the hose is not
kinked or water flow will be affected, chang-
ing the calculated fill time.
STEP 3 : When the furnace is approximately
1/2 full, add the approved Outdoor Wood
Furnace water treatment.
STEP 4 : Continue to fill until the water level
is approximately 1 inch below the bottom of
the vent tube. This will allow for expansion
of the warming water to the proper water
level when the furnace is fired.
STEP 5 : Open any valves and check all installed plumbing for leaks.
STEP 6 : Apply power to the pumps and allow circulation and mixing to
occur of the treated water
NOTE:
If overflow occurs, drain excess water from rear at the reservoir drain
Proper water level is 3-1/2” out of the
Top of the float cap assembly
Water should not be allowed to drop below
2” from the top of float cap assembly.
These Measurements are at operational
temperatures(160-180 deg.)