Operational Procedures
Resetting the computer
Your S4868P furnace is equipped with a fail safe in the event that it should drop be-
low normal operating temperatures for a period of time. This would signify that there is
no heat being created in the firebox. The fail safe prevents the cold outside air from
blowing threw the firebox, helping to prevent a possible freeze up or wasting heat.
Follow these steps to reset the computer.
NOTE: All the required operating parameters are pre-set at the fac-
tory. Do Not try to alter these settings. Doing so may cause oper-
ating problems and will not be covered as a warranty item.
Press and hold these
two buttons (Down
arrow and SET) at the
same time for 1 sec-
ond to reset the com-
puter from a low alarm
(LA flashes intermit-
tently with the current
water temperature).
The blower will start
within 7 seconds.
OR
Disconnecting the power
for a couple of seconds
and turning it back on will
also reset the computer.
Power failures will not
change the settings within
or harm the computer.