Use the
button to m
circuit (HW). Press
the or
button to
Exit with
Press
OK.
-
+
ESC.
Changing the heating regulat
OK.
ESC.
Press the
button to move th
change. Press
the
or
button to ch
Exit with
Press
-
+
Press the
button to move c
HW
Settings
°C
Dom.hot
H1 Select
Heating curve
Settings
Measurements
H1 Settings
Room temp.
Temp drop(w)
Min. limit
Max. limit
Room compens.
Wind compens.
Sun compens.
Pre-increase
Autumn dry
21.5
15
70
4
0
2
0
0
0
Changing the domestic hot w
OUMAN EH-201/L
FOR STARTERS
OUMAN EH-201/L
Congratulations on your excellent choice! You have
arquired a diverse new generation heating regulator
designed for residental and office buildings - most a
top - of - the - line product which can be adapted to the
most diverse locations and heating systems.
Next we will introduce the regulator and the basic
principles for using the user manual.
User panel
Regulating circuit code
Browse button
Group select button
indicates that this is one
circuit heating regulator.
- moves the
> cursor up and down.
-
not in use in Ouman
EH-201/L
The example shows the regulating
circuit's operating mode.
Regulator opens the 3-point
controlled actuator.
Regulator closes the 3-point
controlled actuator.
Height up the pillar shows
the position of he voltage
controlled actuator.
Valve is fully open (100%)
and the control voltage is 10 V.
Valve is fully closed (0%) and
the control voltage is 0 V or
2 V (2 ... 10 V actuator).
Decrease
button
INFO
-button -gives
operating instructions and
additional information on
the display in different situations.
ESC
press to
return to the
previous display
HINT!
When you press + button in adjoining basic display
mode, the regulator displays all the measurement results in
turn and then returns to the basic display mode.
Symbols which indicate
actuator control mode.
Increase -
button
OK
button
H1 Automatic
Outdoor
-15°C
SupplyTemp52°C
>Selection
ESC - press to return to the previous display
Reading the page:
Rate from the basic
display to the topic
of the page.
The colored section
presents the actual topic.
Additional information
about the topic
in question.
Settings that can be changed are
marked on the page in
.
white
OUMAN EH-203
OUMAN EH-203
OUMAN EH-201/L
OUMAN EH-201/L
Ajan asetus
In Ouman EH-201/L the regulator is controlled by many different
settings. By browsing you can see which settings you have in use.
Browsing and setting changes occur in the following way:
Changing the heating regulating circuit setting:
OK.
OK.
ESC.
Press the
button to move the cursor to the setting that you want to
change. Press
Press the or
button to change the setting. Press
Exit with
-
+
Press the
button to move cursor to "Settings". Press
OK.
SETTINGS
Browsing, making changes
6
H1 Select
Heating curve
Settings
Measurements
H1 Settings
Room temp.
Temp drop(w)
Min. limit
Max. limit
Room compens.
Wind compens.
Sun compens.
Pre-increase
Autumn dry
Valve close
GeothHeatAcc
21.5
5
15
70
0
2
25
0
0
55
4
Info button - gives operating instructions
Browse button - moves the cursor up and down
ES C
Press
ESC
until the display no longer changes.
You are then in the "Selection" display shown in the adjoining picture.
OPERATING INSTRUCTION:
Press
OK.
Group select button - not in use in EH201/L
H1
Outdoor
°C
SupplyTemp
°C
Selection
Automatic
-15
52
Explanation:
Room temperature setting, which user has
set.
The supply water temperature drop,
determined by the clock program or the
external home/away switch. (Room
compensation takes a desired drop in room
temperature into account)
Minimum allowed supply water temperature.
Maximum allowed supply water
temperature.
Room compensation ratio: If the room
temperature is different than what it is set at,
the room compensation corrects the supply
water temperature.
(Eg.) If the room compensation is 4 and the
room temperature has risen 1,5 °C above
the setting, the regulator drops the supply
water temperature 6 °C (4x1,5 °C =6 °C).
Wind compensation ratio: A house cools
down in windy weather. In that case the
wind compensation raises the supply water
temperature. The reading indicates the
maximum amount that the wind compens.
can raise the supply water temperature.
Range:
5.0...45.0°C
0...35°C
5...95°C
15...125°C
0...7°C
0...7°C
Factory
settings:
21.5°C
0°C
15°C
70°C
4°C
0°C
Settings:
Room temp.
Temp drop
Min. limit
Max. limit
Room compens.
Wind compens.
(w)
(supply water)
Attention!
During temp. drop period
regulator use the calculated
room temp. setting, which is
INFORMATION ABOUT SETTINGS:
80
65
50
35
20
20 0 -20 °C
Minimum limit
80
65
50
35
20
20 0 -20 °C
Maximum limit
Room sensor
(TMR) must
be connected (Meas.3 or
LON bus).
Room temp. -
Temp drop(w)
Room compens.
Condensed guide
for the buttons.
EH 201/L