CAUTION

Contact with cold, heat, embers or fire

Injuries (e.g. burns) and damage to the product due to unallowable envir­
onmental conditions

Keep the product away from open flames, embers and other sources of
heat.

Do  not  expose  the  product  to  unallowable  environmental  conditions
(see the section "Environmental conditions").

Inform the patient.

NOTICE

Exposure of the product to unsuitable environmental conditions

Damage, brittleness or destruction due to improper handling

Avoid storage in condensing ambient humidity.

Avoid contact with abrasive substances (e.g. sand, dust).

Do  not  expose  the  product  to  temperatures  below  -10 °C  (14 °F)or
above  +60 °C  (140 °F)  (e.g.  sauna,  excessive  sunlight,  drying  on  a
radiator).

Inform the patient.

4 Scope of Delivery

The following single components and accessories are included in the scope
of delivery in the specified quantities and are available for reordering accord­
ing  to  their  respective  symbols  as  single  components  ( ),  single  compon­
ents with minimum order quantities ( ) or single-component packs ( ):

Fig.

Item

no.

Quant

ity

Designation

Reference number

1

 – 

 

 

1

Custom carbon protector

4X889=1

   

 – 

1

Instructions for use

647G979

The following parts are for reorder only as accessories or spare parts

1

   

 

 

0

Knee pad

4P889=G3

   

 – 

0

Rubber closure

4P889=G2

5 Preparation for Use

CAUTION

Improper fitting, application and removal

Injuries and damage due to incorrect handling of the product

12  |  Ottobock

Содержание 4X889-1

Страница 1: ...4X889 1 Gebrauchsanweisung 4 Instructions for use 10...

Страница 2: ...1 2 3 4 2 Ottobock...

Страница 3: ...5 6 7 8 Ottobock 3...

Страница 4: ...ichen ist 1 2 Kombinationsm glichkeiten Nachfolgend sind Prothesenkomponenten aufgef hrt die sich besonders zur Kombination mit dem Produkt eignen Benennung Kennzeichen Prothesenkniegelenk 3B1 3B1 ST...

Страница 5: ...Prothesenkompo nenten ob sie auch untereinander kombiniert werden d rfen VORSICHT Mechanische Besch digung des Produkts Verletzungen durch Funktionsver nderung oder verlust Arbeiten Sie sorgf ltig mit...

Страница 6: ...kondensierender Umgebungsfeuch tigkeit Vermeiden Sie den Kontakt mit abrasiven Medien z B Sand Staub Setzen Sie das Produkt keinen Temperaturen unter 10 C und ber 60 C aus z B Sauna berm iger Sonnene...

Страница 7: ...des Produkts darf nicht mit proximalen Prothesenkomponenten kollidieren Bei Flexion darf der Prothesenschaft nicht mit dem Produkt kollidieren Die Prothese in Flexionsstellung und Extensionsstellung b...

Страница 8: ...zwischen dem Prothesenkniegelenk und dem Produkt einf deln siehe Abb 4 2 Den richtigen Sitz des Ladeadapters am Prothesenkniegelenk berpr fen siehe Abb 5 3 Das Prothesenkniegelenk gem seiner Gebrauch...

Страница 9: ...Sicherheitskontrollen durchf hren 7 1 Austausch des Knieschutzes 1 Den alten Knieschutz vom Produkt entfernen siehe Abb 8 2 Nur die Klebefl che mit einem entfettenden Reiniger von Kleber ckst n den r...

Страница 10: ...urements so its shape matches that of the unaffected leg 1 2 Combination Possibilities Prosthetic components that are especially well suited for combination with the product are listed below Designati...

Страница 11: ...ilities Based on the instructions for use of the prosthesis components verify that they may be combined with each other CAUTION Mechanical damage to the product Injuries due to changes in or loss of f...

Страница 12: ...ratures below 10 C 14 F or above 60 C 140 F e g sauna excessive sunlight drying on a radiator Inform the patient 4 Scope of Delivery The following single components and accessories are included in the...

Страница 13: ...ollision 3 In case of collision Shorten and deburr the product in the collision area Avoid sharp edges and damage to the fibre structure 6 Use 6 1 Handling Applying product to the prosthesis 1 NOTICE...

Страница 14: ...rding to its instructions for use Removing the product from the prosthesis 1 Pull the rubber closure off the pad button see fig 6 2 NOTICE Do not overstretch the product Bend the product apart see fig...

Страница 15: ...ng cleaner 3 Fit the new knee pad and glue it using contact adhesive 4 Allow the adhesive to harden 8 Disposal This product may not be disposed of with regular domestic waste in all juris dictions Dis...

Страница 16: ...m in accordance with ISO 13485 Ottobock 647G979 DE EN 01 1408 Template Version 2014 05 28 FM477 SB_105x148 Otto Bock HealthCare GmbH Max N der Stra e 15 37115 Duderstadt Germany T 49 5527 848 0 F 49 5...