B_PM_UMCbox_en04.doc
4-6
Operation
ÖSTLING Markiersysteme GmbH
2.2 Switching on and off the control
Switching on the control
Electronics damage to control possible!
Control must be switched off for at least 20 s before switching on.
Switch on MAIN SWITCH.
Control boots, axes of the marking head reference: the slide of the marking
head moves in X-direction until the X-initiator actuates. Then it continues to
move in X-direction by the value of "Overtravel" (see page 4-29). The slide
moves likewise in Y-direction. The reached position is defined as basing point of
the marking head. This basing point is the origin of the marking field.
After successful homing the main menu appears:
Main menu
Fig. 10393en