B_PM_UMCbox_en04.doc
4-26
Operation
ÖSTLING Markiersysteme GmbH
7
System control
7.1 Reading out diagnostic data
Select
System > Diagnostic
.
"Diagnostic" appears.
Mask "Diagnostic"
Fig. 10247en
•
Pinware Version: software version that is installed on the control.
•
Install Version: version of the compact flash card.
•
Firmware Version: software version of the motor card.
•
Ambient/Heat sink temperature: temperature of the ambient air in [°C] and
temperature of the heat sink of the motor card in [°C].
•
Machine status:
-
MS: system status, 5-digit. Contains information about temperatures,
voltage ranges and output drivers.
Digit
Description
Status Description of the status
0
Error.
left-
most
Output driver
1
OK.
0
No voltage.
1
Voltage OK.
2
High voltage.
3
To high voltage, error.
4
Low voltage.
2. from
left
Supply voltage: voltage in
[V] that impressed to the
motor card.
5
Too low voltage, error.
Содержание PinMark UMC box
Страница 14: ...B_PM_UMCbox_en01 doc 1 8 Safety ÖSTLING Markiersysteme GmbH ...
Страница 32: ...B_PM_UMCbox_en03 doc 3 12 Description ÖSTLING Markiersysteme GmbH ...
Страница 91: ...B_PM_UMCbox_en07 doc ÖSTLING Markiersysteme GmbH Index 7 1 Chapter 7 Index ...
Страница 94: ...B_PM_UMCbox_en07 doc 7 4 Index ÖSTLING Markiersysteme GmbH ...
Страница 95: ...B_PM_UMCbox_en08 doc ÖSTLING Markiersysteme GmbH Drawings parts lists 8 1 Chapter 8 Drawings parts lists ...
Страница 96: ...B_PM_UMCbox_en08 doc 8 2 Drawings parts lists ÖSTLING Markiersysteme GmbH ...
Страница 98: ...B_PM_UMCbox_en09 doc 9 2 EC declaration of conformity ÖSTLING Markiersysteme GmbH ...
Страница 100: ......
Страница 101: ...B_PM_UMCbox_en10 doc ÖSTLING Markiersysteme GmbH Service request 10 1 Chapter 10 Service request ...
Страница 102: ...B_PM_UMCbox_en10 doc 10 2 Service request ÖSTLING Markiersysteme GmbH ...
Страница 104: ......