B_EU_EMP_en.doc
ÖSTLING Markiersysteme GmbH
Operation manual EMP
22
4.1 Programming a marking with EU CLASSIC
After switching on the equipment is in the main menu. The last set values and
settings remain also after switching off the equipment.
1. Switch on the equipment over MAIN SWITCH (1).
Main menu appears, in the display (2) appears e. g. "MP=08.0 MT=04.0".
In the main menu the pushbuttons AUTOMATIC, TIMER and PUMP have a
function. A program can be started only in the main menu.
2. Press ENTER (6) to enter the submenu "Marking power".
The marking power changes with the impressed voltage. In order to achieve a
long service life of the stencils, the marking power should be selected as small
as possible. Increase the marking time with unsatisfactory marking results first,
before the marking power is increased.
3. To choose alternating or direct current: press =/~ (8).
-
AC (alternating current) for black/white marking.
-
DC (direct current) for deep marking.
LED (3) above the pushbutton shows the selected current type.
4. To increase the marking power: press
↑
(4).
Each press increases the marking power in steps of 0.2 units. The maxi-
mum value is 24.0.
5. To decrease the marking power: press
↓
(5).
Each press decreases the marking power in steps of 0.2 units. The mini-
mum value is 0.2.
6. To reject the settings: press MENU (7).
Main menu appears.
7. To assume the settings: press ENTER (6).
Submenu "Time MT" appears.
During the marking time voltage is impresses and current flows. With very long
marking time the electrolyte heats itself, the stencil becomes hot. The service
life of the stencil is reduced.
8. To increase the marking time MT: press
↑
(4).
Each press increases the marking time in steps of 0.1 s. The maximum
value is 15.0 s.
9. To decrease the marking time MT: press
↓
(5).
Each press decreases the marking time in steps of 0.1 s. The minimum
value is 0.1 s.
10. To reject the settings: press MENU (7).
Main menu appears.
11. To assume the settings: press ENTER (6).
If the options "Pumping time" and/or "Retarder" are activated, the submenu
"Time PT" or "Time RT" appears. Otherwise the main menu appears.
Setting the
marking power
Setting the