B_EU_EMP_en.doc
ÖSTLING Markiersysteme GmbH
Operation manual EMP
15
1. Loosen the 3 upper screws on both sides of the equipment.
2. Take off the cover of the equipment.
Transformer appears:
1
Fuse magnet valve
2
Sticker technical data
3
Preset input voltage (here: 230 V)
Transformer Fig.
10014
3. Set the desired input voltage with the jumpers as shown on the sticker (2).
The net frequency (50 or 60 Hz) is automatically detected by the equipment.
Note
The 24V, DC output (output magnet valve) is secured with a second fuse (1)
additionally to the magnet valve fuse on the back of the equipment. This fuse
prevents the destruction of the internal jumper rectifier with a overcurrent
(>1 A), which can be caused e.g. by a short-circuit. The rated current intensity
of the fuse stands on the sticker (2).