SECTION 4 - MACHINE OPERATION
31215048
4-13
Telescoping the Main Boom
To extend or retract the boom, use the Telescope
Control Switch to select In or Out movement.
4.8
FUNCTION SPEED CONTROL
This control affects the speed of Telescope and
Swing. Turning the knob all the way counter
-
clockwise until it clicks puts the Drive, Main Lift,
Telescope, and Swing into Creep mode.
4.9
MACHINE SAFETY SYSTEM OVERRIDE (MSSO)
(CE ONLY)
The Machine Safety System Override (MSSO) is
used to override function controls for Emergency
Platform Retrieval only. Refer to Section 5.5,
Machine Safety System Override (MSSO)(CE Only)
for operating procedures.
4.10 SKYGUARD OPERATION
SkyGuard provides enhanced control panel protection. When the
SkyGuard sensor is activated, functions in use at the time of actu
-
ation will reverse or cutout. The SkyGuard Function Table pro
-
vides more details on these functions.
During activation, the horn will sound and, if equipped with a
SkyGuard beacon, the beacon will illuminate until sensor and
footswitch are disengaged.
If the SkyGuard sensor remains activated after function reversal
or cutout, depress and hold the SkyGuard Override Switch to
allow normal functions until the sensor is disengaged.
Consult the following illustrations to determine which type of
SkyGuard the machine has and how it is activated. Regardless of
type, SkyGuard function according to the SkyGuard Function
Table does not change.
To