SECTION 4 - MACHINE OPERATION
31215036
4-7
Fuel Reserve / Shut-Off System
NOTE:
Reference the Service and Maintenance Manual along with a
qualified JLG Mechanic to verify your machine setup.
The Fuel Shutoff System monitors the fuel in the tank and senses
when the fuel level is getting low. The JLG Control System auto
-
matically shuts the engine down before the fuel tank is emptied
unless the machine is set up for Engine Restart.
If fuel level reaches the Empty range, the Low Fuel
light will begin to flash once a second and there will
be approximately 60 minutes of engine run time left.
If the system is in this condition and automatically
shuts down the engine or if the operator manually
shuts down the engine before the 60 minute run time
is complete, the Low Fuel light will flash 10 times a
second and the engine will react according to
machine setup. Setup options are as follows:
• Engine One Restart - When the engine shuts down, the
operator will be permitted to cycle power and restart the
engine once with approximately 2 minutes of run time.
After the 2 minute run time is complete or if the engine is
shut down by the operator prior to the completion of the 2
minute run time, it cannot be restarted until fuel is added
to the tank.
• Engine Restart - When the engine shuts down, the opera
-
tor will be permitted to cycle power and restart the engine
for approximately 2 minutes of run time. After the 2 min
-
utes of run time is complete, the operator may cycle power
and restart the engine for an additional 2 minutes of run
time. The operator can repeat this process until there is no
more fuel available.
CONTACT A QUALIFIED JLG MECHANIC IF THE MACHINE NEEDS RESTARTED AFTER NO
MORE FUEL IS AVAILABLE.
• Engine Stop - When the engine shuts down, no restarts
will be permitted until fuel is added to the tank.