6.1
SKYPOWER™
The generator supplies AC power through an AC receptacle in the
platform to run tools, lights, and cutting and welding equipment .
All power regulation components are located in a watertight box
connected by cable to the generator. The generator supplies
power when running at the specified speed with the power
switch on (switch is located on platform). A three-pole, 30 Amp
circuit breaker protects the generator from overload.
Generator Output
ANSI Specs:
240V;60Hz; 3-Phase; 7.5kW and 240V/120V:60Hz; Single
Phase:6kW.
CE Specs:
3-phase, 240-volt, 7.5kw, 18.3-amps, 1.0-pf
1-phase, 240 volt, 6.0kw, 26-amps, 1.0-pf
1-phase, 120 volt, 6.0kw, 50-amps, 1.0-pf
Peak:
3-phase 8.5kw
1-phase 6.0kw
Accessory Ratings
Safety Precautions
• Do not over load platform.
• Make sure no personnel are beneath platform.
• Keep lanyard attached at all times.
• Do not use electrical tools in extremely wet conditions.
• Use correct voltage for tool being used.
• Do not over load circuit.
Drive -Type
Generator Speed
Belt-Drive/Pulley
3000rpm (50 Hz)
3600 rpm (60 Hz)