OPERATING & INSTALLATION INSTRUCTIONS FOR STRATFORD CF ZERO CLEARANCE WOOD HEATER
43
7.2
Minimum Clearances to Combustibles, and Floor Protector
CLEARANCES
G
200 mm -
Note 1
H
1130 mm -
Note 2
I
1230 mm -
Note 2*
O
70 mm maximum
MINIMUM OPENING
J
1135 mm
K
1120 mm
L
658 mm
FLOOR PROTECTION**
B
500 mm
M
1185 mm
N
1125 mm
CLEARANCES
F
90 mm
P
80 mm
Q
155 mm
Note 1:
From door opening.
Note 2:
From appliance’s base. Does not include the 90 mm required raised base above the floor
protection.
Note 3:
The first internal wall stud must be 275 mm above the zero clearance wood inbuilt top and the
front wall above the fireplace must be made of non-combustible material.
*FOR A 250 MM MAXIMUM MANTEL SHELF.
** REFER TO AS 2918 – 1990 CLAUSES 2.2, 3.3.1, 3.3.2 AS THERE ARE VARIATIONS TO THE CONSTRUCTION
OF HEARTHS.