background image

4. How to use

The  detector’s PCB and battery holder  are  placed in a plastic enclosure with a removable

cover (Figure 1).

A pyrodetector, tamper switch, a multi-color LED indicator, battery holders and 

RESET

 contacts

to initiate the process of binding with the Lun-R receiver are placed on the detector’s PCB.

Figure 1. Detector and its cover

At the bottom of the board is a terminal block for connecting an external antenna.

PIROUT-R

Version en_2

4

Содержание PIROUT-R

Страница 1: ...with operating modes and conditions therefore this document require ments is mandatory Outdoor Motion Detector PIROUT R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiv...

Страница 2: ...hnical specifications 3 4 How to use 4 4 1 Modes Indication 5 4 2 Binding 5 4 3 Wireless signal strength 6 4 4 Installing 6 4 5 Adjusting 7 5 Maintenance 7 6 Operating conditions 7 7 Storage 8 8 Trans...

Страница 3: ...senting the danger of electric shock to a per son No safety ground 3 Technical specifications The detector technical characteristics is shown in the Table 1 Table 1 Technical characteristics Character...

Страница 4: ...pyrodetector tamper switch a multi color LED indicator battery holders and RESET contacts to initiate the process of binding with the Lun R receiver are placed on the detector s PCB Figure 1 Detector...

Страница 5: ...tor modes displays by multicolored LED Norm light off Alarm flashing red once every 4 seconds upon the moving people or large animals see section 4 are detected This flashing will operate up to 15 min...

Страница 6: ...e Avoid getting into the detector detection area of obstacles whose temperature can change significantly for example a wall heated by the sun To install the detector 1 The detector is mounted on any f...

Страница 7: ...cide with the necessary ones then the detector position on the bracket should be adjusted turn it and or tilt to the corresponding side To do this slightly loosen the screws that secure the bracket ro...

Страница 8: ...eriod or insulators must be installed in the battery holders 8 Transportation 1 Detector transportation shall be carried out in the manufacturer s package 2 Detector is allowed to be transported by al...

Страница 9: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io PIROUT R Version en_2 9...

Отзывы: