background image

1. Purpose

The PIROUT-R detector (hereinafter referred to as the “detector”) is designed to detect a pene-

tration into the space around the protected objects and transmit this events to the Lun-R receiver
that is connected to the Lun control panel (more about for compatibility, see the documentation of

the relevant control panel).

Product is not equipped with built-in cameras and microphones, devices and units for

hidden video and audio recording.

2. Safety Precautions

Only the employees, familiar with the module design, instructed on the safety arrangements

shall be allowed to install, routinely maintain and repair.

The device does not have open live parts, representing the danger of electric shock to a per-

son. No safety ground.

3. Technical specifications 

The detector technical characteristics is shown in the Table 1.

Table 1. Technical characteristics

Characteristic

Value

Operating frequency range (depends of modification), MHz

433.05…434.79 or

868.70…869.20

Power radiated by the transmitter, mW

up to 10

The health test signals period, seconds

60

Installation height, m

2…3

The angle of the detection zone in the horizontal plane

90º

Maximum range with installed/removed jumper 

SENS HIGH

, m

12/8

Detectable speeds range, m/s

0.3…3

Main and backup power source type

CR123A battery

Battery voltage, V

2.2…3.2

The battery predicted service life, years

up to 5

Degree of protection provided by enclosure

IP54

Dimensions, mm

180*75*80

Weight, g

200

The detector detection zone diagram is shown in Figure 2.

PIROUT-R

Version en_2

3

Содержание PIROUT-R

Страница 1: ...with operating modes and conditions therefore this document require ments is mandatory Outdoor Motion Detector PIROUT R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiv...

Страница 2: ...hnical specifications 3 4 How to use 4 4 1 Modes Indication 5 4 2 Binding 5 4 3 Wireless signal strength 6 4 4 Installing 6 4 5 Adjusting 7 5 Maintenance 7 6 Operating conditions 7 7 Storage 8 8 Trans...

Страница 3: ...senting the danger of electric shock to a per son No safety ground 3 Technical specifications The detector technical characteristics is shown in the Table 1 Table 1 Technical characteristics Character...

Страница 4: ...pyrodetector tamper switch a multi color LED indicator battery holders and RESET contacts to initiate the process of binding with the Lun R receiver are placed on the detector s PCB Figure 1 Detector...

Страница 5: ...tor modes displays by multicolored LED Norm light off Alarm flashing red once every 4 seconds upon the moving people or large animals see section 4 are detected This flashing will operate up to 15 min...

Страница 6: ...e Avoid getting into the detector detection area of obstacles whose temperature can change significantly for example a wall heated by the sun To install the detector 1 The detector is mounted on any f...

Страница 7: ...cide with the necessary ones then the detector position on the bracket should be adjusted turn it and or tilt to the corresponding side To do this slightly loosen the screws that secure the bracket ro...

Страница 8: ...eriod or insulators must be installed in the battery holders 8 Transportation 1 Detector transportation shall be carried out in the manufacturer s package 2 Detector is allowed to be transported by al...

Страница 9: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io PIROUT R Version en_2 9...

Отзывы: