Depending on external actions, the detector transmits the following events to the Lun-R re-
ceiver:
●
If there are no moving people or large animals in the detection zone, then the
norm
event is generated;
●
If moving people or large animals are detected, then the
alarm
event is generated;
●
If the housing cover is opened, the tamper will be triggered and the
tamper alarm
event
will be generated;
●
If the voltage of the main battery drops to 2.4V or lower – the event "
Main battery low
" is
generated;
●
If the voltage of the backup battery drops to 2.4V or lower – the event "
Backup battery
low
" is generated.
In addition, the detector transmits periodic test signals to the receiver to confirm its operabil-
ity. When the test signals stop, the control panel generates the
detector communication lost
event.
The detector provides protection against the following types of interference (false alarms):
Medium-sized animals movement (up to 20 kg weight) on the floor;
Illumination drops up to 20,000lx;
Changes in temperature of objects at a speed of up to 5ºС per minute.
When the communication loss with the receiver, the detector continues to search it. Therefore,
when you turn off the receiver or control panel for a long time, it is recommended to remove the
detector’s batteries.
4.1. Modes Indication
The detector modes displays by multicolored LED:
Norm
– light off;
Alarm
– flashing red once every 4 seconds – upon the moving people or large animals
(see section 4) are detected. This flashing will operate up to 15 minutes after the detec-
tor’s cover is closed then flashing stops to conserve the battery;
Binding
– blinking green while waiting for a signal from the Lun-R receiver to register in
the control panel memory;
Bound
– when the binding is completed successfully – turning on red for 2…3 seconds.
4.2. Binding
A new detector must be bound to the control panel in order to successfully transmit its com-
mands to the receiver.
To register a detector, do the following:
1. In the control panel configuration, pre-set the required number of radiozones, their type,
group membership and other parameters;
2. Turn on the control panel in the operating mode and switch to the desired control
panel’s group;
3. Switch the control panel to the wireless detectors binding mode (see the corresponding
control panel programming manual);
4. Install the battery to the detector observing polarity –
BACKUP
first then
MAIN
;
5. Switch the detector to the binding mode by short-circuit the
RESET
contacts for 2…3 sec-
onds (until the blinking green – the signal "
Binding
");
6. Binding will processed automatically and, if successful, ends by turning on the red LED
for 2…3 seconds (signal "
Bound
").
The detector waits 70 seconds for binding. To reinitialize the binding process, briefly close the
RESET
contacts again.