Page
4 / 19
Type
Numb.
Net heat output
Boiler dimension (mm)
Combustion chamber dim.
sect.
kW
(kcal/h)
Height
Width
Depth
Height
Width
Depth
3.0
5
56,00-60,47
49-52000
1110
626
733
420
370
410
4.0
6
68,61-82,57
59-71000
1110
626
733
420
370
513
5.0
7
83,76-97,69
72-84000
1110
626
939
420
370
616
6.0
8
98,95-112,81
85-97000
1110
626
939
420
370
719
7.0
9
113,97-127,93
98-110000
1110
626
1145
420
370
822
8.0
10
129,09-137,07
111-117000
1110
626
1145
420
370
925
O pti major GLP S
N°
CE 9 2 / 4 2
OPTIM AZ C E 9 2 /4 2
OPTIM AZ CE 9 2 / 4 2
OPTIM AZ CE 9 2 / 4 2
OPTIM AZ C E 9 2 /4 2
OPTIM AZ CE 9 2 / 4 2
OPTIM AZ
Re qu ire d draught (mbar)
0,13
0,1
0,2
0,11
0,20
0,13
0,25
0,15
0,32
0,19
0,41
0,22
Gas side re sistance and combusti on
chambe r pre ssu re (mbar)
0,08
0,04
0,11
0,06
0,15
0,08
0,2
0,1
0,27
0,14
0,36
0,17
T° flu e - T° ambiance
200
165
197
165
194
165
191
165
188
165
184
165
Exi t flue gas mass flow (g/s)
28
19
35
25
42
30
50
35
57
40
64
45
He at input
60,77
43,39
76,56
54,67
92,36
65,95
108,15
77,22
123,95
88,5
139,74
99,78
Max. he at input (kW )
67,6
48,1
84,7
60,3
101,9
72,5
119
84,7
136,2
96,6
153,3
109,2
C ombusti on circui t vol. (dm³)
Wate r si de l osse s (mbar)
1,7
0,9
2,7
1,4
3,9
2
5,3
2,7
6,9
3,5
8,7
4,4
Re l ative standby loss (%)
Wate r capacity (l )
Packe d we ight (kg)
545
595
345
395
445
495
70
77,5
0,35
0,31
40
47,5
55
62,5
0,27
0,23
7.0
8.0
76,1
84,9
0,19
0,15
40,9
49,7
58,5
67,3
3.0
4.0
5.0
6.0
2. Layout of the heating installation
The installer must make the necessary arrangements on site to ensure that the positioning and the the fitting of the boiler,
the supply of combustion air, ventilation of the boiler house, connection of the gas supply, the removal of the combustion
gases via the flue system and the electrical connections are in conformity with the operational characteristics of the material
and in accordance with the rules of the trade and the prevailing regulations.
In the following paragraphs, Saint Roch Couvin remind you of some rules concerning the above aspects. If the conditions
summarised above are not strictly adhered to and resulting damage occurs then our guarantee would be invalidated.
732.8 *
10
09
.3
11
63
.3
401.8
600
313
626
33
0
313
65
67
0
85
0
P
1
0
1
0
1
1
6
5
402
Burner
opening
Ø 130
Drain cock
Ø 3/4"
Flow
Ø 2"
Flue gas
Ø 200
Return
Ø 2"
1. Technical data